• Sonuç bulunamadı

BelhhanAkpinar*,MustafaGuden Theuseofcompositestentlessvalveswithgraftextensionforthetreatmentofascendingaorticaneurysms

N/A
N/A
Protected

Academic year: 2021

Share "BelhhanAkpinar*,MustafaGuden Theuseofcompositestentlessvalveswithgraftextensionforthetreatmentofascendingaorticaneurysms"

Copied!
1
0
0

Yükleniyor.... (view fulltext now)

Tam metin

(1)

Letter to the Editor

The use of composite stentless valves with graft extension for the

treatment of ascending aortic aneurysms

Belhhan Akpinar*, Mustafa Guden

Kadir Has University, Florence Nightingale Hospital, Department of Cardiac Surgery, Istanbul, Turkey Received 7 September 2001; accepted 24 September 2001

Keywords: Freestyle; Stentless valve; Ascending aortic aneurysm

We read with interest the article from Dr Byrne and his associates [1] concerning the use of composite stentless valves with graft extension for combined replacement of the aortic valve, root and ascending aorta. As the authors have kindly pointed out, our first article concerning this technique was published in 1999 [2]. We have used this technique on well over 40 patients with this pathology since 1996 and our latest experience was presented during a meeting in Europe [3]. We believe there are some impor-tant technical details that have to be addressed.

In our experience distal aortic cannulation was used only for limited aneurysms with a fine distal neck. However, in most of the cases we had to use femoral or axillary artery cannulation and perform an open distal anastomoses under circulatory arrest, which in our experience was more feasi-ble.

An important concern should be the length of the Hema-shield graft. The anastomoses lines between the Freestyle and the Hemashield graft as well as the left ventricular outflow and the Freestyle should be tension free. The graft should not be short, otherwise this can cause excessive tension on the suture line and end up with late dehiscence and false aneurysm formation. The quality of the porcine aortic wall can be less than ideal in some valves and we have adopted to incorporate a strip of pericardium in the suture line between the hemashield and Freestyle to prevent this complication.

Late aortic wall calcification is a concern. However, our follow up in two valves up to 5 years [4] has encouraged us that this would not be a problem, at least for the mid-term. We do not share the opinion of the authors on the feasi-bility of inserting a stented valve within the Freestyle valve when a reoperation becomes necessary. Although we did not

have to reoperate on any of these cases so far, we have experienced two reoperations with the Edwards Prima valve which we had used previously and we had to perform a re-root replacement since it was not feasible to implant another valve within the conduit. The main problem was the suture line between the stentless valve and the LVOT which had become extremely calcific and it was not possible to put stitches through this tissue. Even if this is possible, then you have to implant a stented valve that is one to two sizes smaller which may not be ideal for the patient.

In conclusion, we agree with the authors that this is a reproducible technique that is advisable for patients with this pathology that can not use anticoagulation. However, until long term results with these valves are available, we believe that this technique should be reserved for patients over 65 years of age.

References

[1] Byrne JG, Mihaljevic T, Lipson E, Smith B, Fox J, Aranki S. Compo-site stentless valve with graft extension for combined replacement of the aortic valve root and ascending aorta. Eur J Cardiothoracic Surg 2001;20:252–256.

[2] Akpinar B, Sanisogˇlu I, Konuralp C, Guden M. The use of stentless porcine bioprosthesis to repair an ascending aortic aneurysm in combi-nation with aortic valve replacement. Tex Heart Inst J 1999;26:195– 197.

[3] Akpinar B, Sanisogˇlu I, Guden M, Sagbas E. The use of stentless valves as composite grafts for the repair of ascending aortic aneurysms with aortic valve insufficiency. The European Society for Cardiovascular Surgery,50’th International Congress June 20–23, Budapest, Hungary 2001.

[4] Akpinar B, Guden M, Memis,ogˇlu E. Screening of a stentless valve with EBT 5 years after operation. Eur J Cardiothoracic Surg 2001(19):929. European Journal of Cardio-thoracic Surgery 20 (2001) 1278

1010-7940/01/$ - see front matter q 2001 Published by Elsevier Science B.V. PII: S 1 0 1 0 - 7 9 4 0 ( 0 1 ) 0 1 0 1 0 - 7

www.elsevier.com/locate/ejcts

* Corresponding author. Tel.: 190-212-2244950; fax: 190-212-2398791. E-mail address: belh@turk.net (B. Akpinar).

Referanslar

Benzer Belgeler

The technique of using the Freestyle valve and a Dacron tube graft provides a good alternative for patients who have an aortic aneurysm and require replacement of both

The aim of this experiment is to find the operating voltage range of an Anthracene crystal detector and determine the optimal operating voltage for the further

Hypertrophic cardiomyopathy (HCM), a common genetic heart disease characterized by ventricular hypertrophy, im- paired ventricular relaxation, and myocardial fibrosis, is

Comparison of pressure waveforms reveal that the large PP and equalization of LV and Ao waves in late diastole were similar before and after TAVR Ao - aorta; AR -

Transesophageal echocardiography demonstrates thick- ened and little calcified aortic valve and concomitant rheumatic involvement of the mitral valve in long-axis view of the

During catheterization we realized that the entire aorta, from the iliac bifurcation to aortic cusps, had severe calcification resembling a porcelain tube (Fig.1, Video 1. See

Right heart catheterization showed normal pulmonary artery, right ventricular and right atrial pressu- res and 1+ mitral regurgitation were observed in left ventriculog-

Background:­ In this study, we compared the early outcomes of sutureless aortic valves versus conventional stented bioprosthetic valves.. Methods: Between October 2009