• Sonuç bulunamadı

Assessment of a Three-Dimensional Operating System with Skill Tests in a Pelvic Trainer

N/A
N/A
Protected

Academic year: 2021

Share "Assessment of a Three-Dimensional Operating System with Skill Tests in a Pelvic Trainer"

Copied!
1
0
0

Yükleniyor.... (view fulltext now)

Tam metin

(1)

Assessment of a Three-Dimensional

Operating System with Skill Tests in a Pelvic

Trainer

邱文祥

Sun;Chi-Cheng;Chiu;Allen

W.;;Chen;Kuang-Kuo.;Chang;Luke S;

摘要 Abstract

Objectives: To compare the performance of laparoscopic skill assisted by a traditional two-dimensional (2D) and a three-dimensional (3D) endoscopic video system in a pelvic trainer. Materials and Methods: The 3D imaging system (DeepVision®, Automated Medical Products Corp.) consists of a traditional single lens optic laparoscope, a light source, an endoscopic camera (Stryker), a DeepVision processor and a DeepVision monitor. The 2D images could be obtained with the same system without turning on the DeepVision processor. Thirty-four medical personnel with no laparoscopic surgical experience were enrolled to perform two skill tests, the object-pick-up and spatial orientation test in a trainer box. They were randomly divided into two groups, one group performed the test under 2D conditions first and 3D later, and another group performed the test under 3D conditions first and 2D later. The duration needed to complete the skill tests was recorded and the differences on performance time under 2D and 3D conditions were calculated for each participant. Two-way ANOVA was used to analyze the statistic difference on the performance time in two conditions. Results: The duration needed to complete the initial skill tests was similar among 2D and 3D conditions. For both tests, the average performance time decreased significantly for the second attempt regardless of 2D or 3D conditions. Statistic analysis disclosed significant difference for learning factor (p < 0.001 for object-pick-up test and p < 0.01 for spatial orientation test), but no significant difference betwen 2D and 3D conditions (p = 0.276 for object-pick-up test and p = 0.327 for spatial orientation test). Conclusion: A significant decrease of the performance time at the second attempt reflected the importance of a learning process in laparoscopic surgery. It appears that no significant benefits were obtained by this 3D operating system for surgeons without laparoscopic surgical experience.

Referanslar

Benzer Belgeler

The mean of ICP between two measurements was significantly correlated (r = .93, p &lt; .001) at head 0 degree position, and the bias (mean difference) showed significant differences

Peyzaj Kimlik Özelliklerini Değerlendirme Matrisi - Matrise Eklenmesi Önerilen Bileşenler, Algısal Nitel Özellik Kimlik Bileşenleri.. Kaynak: Şahin, Perçin, Kurum, Uzun, ve

Factors that affect the performance of a reconfigurable mold tool such as the width of support blocks, the length of the pins, the pin-to-adjacent-pin height differential, the

The two way constraints (the residual capacity constraints on deliverable goods and empty space constraints availing picking of loads) imposed by the simultaneous delivery and pick

In conditional convergence it is clear that if countries possess same fundamental economic parameters those countries will converge to the same level of income per worker,

Yalnız tiyatro sanatçısı ola­ rak değil, operet ve revü yıldızı ve sinema oyuncusu olarak da yurt düzeyinde büyük bir ün sahibi olan Muammer Karaca, tam

It first starts with how tensors and matrices used in PARAFAC- ALS will be represented as RDDs in Spark context, then moves on to describe the key implementation steps of MTTKRP such