Design a stability-detecting device for dental implants.

林哲堂

Huang HM;Cheng KY;Chen CF;Lin C-T;Ou KL;Lee SY

Abstract

Resonance frequency (RF) analysis technology was used to design a dental implant stability detector. The device uses a miniature-sized electromagnetic triggering rod to elicit vibration in a dental implant. Vibrational signals were recorded via an acoustic receiver. To assess the in vivo performance of the test apparatus, animal models were used. Implants were placed in the left tibia of 12 rabbits using a conventional surgical procedure. Standard 3.2 mm x 8 mm implants were placed in each test tibia with pre-tapping cavities of 3.2 mm and 3.7 mm diameters to simulate either a 'well-fitting' or a 'loosely fitting' situation. The RF values of the test implants were detected by the newly developed device which was directly mounted on the healing abutments of the implants. The results showed that the RF values of the implants under well-fitting conditions significantly increased (p < 0.01) 3 weeks after surgery and reached a plateau at around 6-7 weeks. Meanwhile implants with higher initial RF values had shorter healing times and higher final RF values at the plateau. Based on these findings, it was concluded that the idea of using the current designed device for detecting the degree of bone healing during the osseointegration process seems feasible.

Referanslar

Benzer Belgeler

Since the signal output from the sensor is in microvolts range, it was necessary to use a high gain to boost the signal level so that it can be better observed and

The device is low-cost and is based on using a weight measuring load cell together with a low-cost microcontroller development system in order to measure the weight of the

(1987) made, &#34;An Analytical Study of Traditional Muslim System of Education and its Relevance in the Modern Indian Context.&#34;3oi. Objectives: The objectives of the

Çalışmada kullanılan altı adet tavşan gelişigüzel olarak bilateral overektomi uygulanan (BO, n:2), bilateral overektomi uygulanan ve östrojen reseptör

In this study, Naproxen was placed in a polar solvent, such as methanol, while it exposed to high pressure mercury lamp, it undergoes photodegradation.. The photodecomposition

I N CHARACTERIZATION of rf-SQUIDs, the effect of the used electronics (rf-pumping frequency and applied power) and tank circuit on the flux to voltage transfer function, , is

Turkey also has a national guide of family plan- ning services and contraceptive use prepared by the Turkish Ministry of Health 6, 9.. Use of the national fa- mily planning