• Sonuç bulunamadı

Step 1. Irradiation (25 mGy)

N/A
N/A
Protected

Academic year: 2021

Share "Step 1. Irradiation (25 mGy) "

Copied!
2
0
0

Yükleniyor.... (view fulltext now)

Tam metin

(1)

AIM: (a) to perform a dose response curve for TLD 100, (b) to get familiar with the annealing procedure before measurements and (c) to calculate the unknown dose accumulated by another TLD 100 chip, using the dose response curve of the previous step.

Materials: Lithium fluoride (TLD 100, LiF:Mg,Ti) or BeO or alumimum oxide

PROTOCOL:

At the beginning, the optimum annealing conditions should be found and followed, according to the reference book below. Annealing should be performed following the exact conditions, depending on the dosimeter used.

Step 1. Irradiation (25 mGy)

Step 2. TL measurement (350 °C, HR=1°C/s)

Step 3. TL measurement (350 °C, HR=1°C/s) for background

Step 4. Repeat steps 1-3 changing the dose applied in step 1 (50 mGy, 75 mGy, 100 mGy, 125 mGy, 150 mGy, 200 mGy, 250 mGy). Each dose should be applied to another chip dosimeter.

Analysis:

1. Plot the TL signal of the main dosimetric peak versus dose. Check whether linear or saturation exponential fitting could be performed.

2. Calculate the minimum detectable dose limit for the material/dosimeter applied.

3. You will be given another dosimeter, which has been irradiated with an unknown dose. Measure the signal of this dosimeter and based on the dose response curve that you have plotted previously, calculate this unknown dose that was absorbed by the dosimeter.

Reference: S.W.S. McKeever, M. Moscovitch, P.D. Townsend, Thermoluminescence

Dosimetry Materials: Properties and Uses, Nuclear Technology Publishing, 1995.

(2)

Fig. 1. Dose response curve for very low doses for CaF

2

:N dosimeter.

Referanslar

Benzer Belgeler

Following these assumptions, in this paper, it will be analysed the traditional understanding of human rights as included in the UDHR of 1948 and how human rights have

The injured Coliforms bacteria were recovered and the count was exceeded the limits in four brands (Chyaw, Amca, Twin and Mufid) while no coliforms bacteria had been detected

AIM: To check the different shape of the glow curves of each material and to assess the number of peaks present.. Irradiation (0.5 Gy for synthetic materials, 15 Gy for

AIM: to get familiar with the Linearly Modulated OSL (LM-OSL) signal and check the behavior of the LM-OSL measurements versus various stimulation parameters. Check the shape of

biopsy material is removed by the aid of scapel and a fine needle. c, d) Proximal part of the the nail plate is avulsed to check for remaining part of the lesion. e)

The present study observed that the celebrity endorsement acts an important role in the Indian tourism service industry, that fall in the category of limited

In the first part, this research using ‘National Health Insurance Research Database in 2003’ to estimate medical costs with 318 patients who have Thalassemia Major. And

Daha sonra bu kara delikler birleşip, öteki yıldız artıklarıy- la beslenip büyüyerek süper kütleli kara delikler haline geliyorlar.. Bu varsayımın doğruluğunu sına- mak