Determination of Diclofenac in Subretinal and Aqueous Humor Fluids by HPLC with Electrochemical Detector

N/A
N/A
Protected

Academic year: 2021

Share "Determination of Diclofenac in Subretinal and Aqueous Humor Fluids by HPLC with Electrochemical Detector"

Copied!
7
0
0

Yükleniyor.... (view fulltext now)

Tam metin

(1)

INTRODUCTION

Diclofenac sodium is a non-steroidal anti- inflammatory drug (NSAID) with analgesic, anti- inflammatory and antipyretic properties. These properties are primarily achieved by its ability to

block the enzyme cyclooxygenase in the arachidonic acid cascade and to decrease prostanoid synthesis, but also by an additional direct effect on hyperalgesia due to the functional downregulation effect of sensitized peripheral pain receptors1,2. The efficacy of diclofenac is equal to that of many newer NSAIDs,

*

**

º

Hacettepe University, Faculty of Pharmacy, Department of Analytical Chemistry, 06100, S›hhiye, Ankara, TURKEY Ministry of Health, Ankara Education and Research Hospital, Eye Clinics, Ankara, TURKEY

Corresponding author e-mail: [email protected]

Determination of Diclofenac in Subretinal and Aqueous Humor Fluids by HPLC with Electrochemical Detector

Diclofenac is used for the treatment of ocular pain because of its inflammatory efficacy. A sensitive and selective bioanalytical method for determination of diclofenac in human eye layers, subretinal and aqueous humor fluids, using reversed-phase HPLC with electrochemical detection (ECD) is described.

Chromatographic separation was achieved by Nucleosil 100-5 C18 (5 µm, 250 x 4.6 mm i.d.) analytical column. The mobile phase consisted of acetonitrile (containing 0.065% triethylamine) and 1.65% glacial acetic acid (50:50, v/v) (pH: 4.30) at a flow rate of 1.0 ml/min. A working potential of 1000 mV for ECD was selected. The method was linear between 20-1000 ng/ml of diclofenac concentration. The limit of detection (LOD) was 10 ng/ml and the limit of quantitation (LOQ) was 20 ng/ml for diclofenac. The intra-day and inter-day bias values were found to be less than 1.72 and 1.14%, and the intra-day and inter-day relative standard deviation (RSD) values were not higher than 2.19 and 1.94%, respectively. The human eye fluids (subretinal and aqueous humor) obtained from patients topically instilled Voltaren® eye drops before retina décollement surgery were analyzed using the presented method. The developed and validated HPLC-ECD method was successful for quantitative determination of diclofenac levels in subretinal and aqueous humor fluids.

Key Words : High performance liquid chromatography (HPLC), NSAID, subretinal, aqueous humor, Voltaren®.

Received : 04.04.2006 Revised : -

Accepted : 24.04.2006

(2)

and it has a fast onset and long-duration analgesic action. Compared to other NSAIDs, diclofenac is well tolerated and rarely produces gastrointestinal ulcerations or other serious side effects. Thus, diclofenac can be considered as one of a few NSAIDs of first choice used in the treatment of acute and chronic painful and inflammatory conditions3-5. In ophthalmology, the well-tolerated anti-inflammatory drug (NSAID) diclofenac sodium is used for perioperative applications in cataract surgery to maintain mydriasis, for prophylaxis, and for treatment of postoperative symptoms of inflammation.

Diclofenac sodium eye-drops are used in ophthalmology to decrease intraoperative miosis and to reduce the breakdown of the blood-aqueous barrier, thus its penetration6-8. Several methods for the determination of diclofenac in biological fluids have been reported. Recently, gas chromatographic methods9-16 have been replaced by liquid chromatographic methods17-20. High performance liquid chromatography (HPLC) with ultraviolet detection is the most popular method for quantification of diclofenac. Nevertheless, these methods have some shortcomings, like a lack of sensitivity and poor specificity, and therefore they are liable to interference from diclofenac metabolites or other endogenous compounds. Ultraviolet detection of diclofenac in synovial fluids is described after involving n-hexane liquid-liquid extraction step18. The prediction of diclofenac penetration to subretinal and aqueous humor fluids has a clinical importance.

HPLC method for diclofenac determination in aqueous humor using fluorescence19 and ECD20 has been described; however, the former requires ETFE r e a c t o r o n - l i n e p o s t c o l u m n s a m p l e photoderivatization and the latter hydrophilic polyoxyethylenepolymer-coated octyl (C8) column.

In addition, they utilize external calibration and do not cover diclofenac determination in subretinal fluid, which has an important eye layer for drug penetration in ophthalmology. In this paper, we describe a simple and specific method for quantitative determination of diclofenac in subretinal and aqueous humor samples.

MATERIALS AND METHOD Chemicals and reagents

Diclofenac sodium was donated by Novartis ‹laç San.

A.fi., and quinine, the internal standard (IS), was obtained from Sigma. HPLC grade acetonitrile was purchased from Lab-Scan (Dublin, Ireland), and glacial acetic acid and triethylamine from J.T. Baker (Deventer, Holland).

Equipment

Chromatography was performed by a Shimadzu liquid chromatograph equipped with a pump (LC- 10AT VP), a controller (SCL-10A VP) connected to a computer using a software (Class-VP 5.03), an autosampler (SIL-10AD VP) and electrochemical detector (Decade). pH of the solutions was measured by a pH meter (Mettler Toledo MA 235).

Chromatographic conditions

The separation was performed on a reversed phase Nucleosil 100-5 C18 (250 x 4.6 mm, 5 µm particle size) column. The mobile phase consisted of acetonitrile (containing 0.065% triethylamine) and 1.65% glacial acetic acid (50:50, v/v) (pH: 4.30). The mobile phase was prepared daily, filtered, sonicated before use and delivered to the system at a flow rate of 1.0 ml/min at room temperatures (20-22°C). The working potential was set to 1000 mV at electrochemical detector. Glassy carbon working electrode was used against to the Ag/AgCl reference electrode.

Standard and sample preparation Standard solutions

Initial stock solutions of diclofenac and quinine (as IS) (1000 µg/ml) were prepared by dissolving 5 mg of each compound in 5 ml of methanol. Intermediate standard solutions (10 and 1 µg/ml) were diluted from the primary stock solution using mobile phase.

Stock and intermediate solutions were stored at 4°C and remained stable for at least six months. Working

(3)

standard solutions (20, 50, 100, 200, 400, 600, 800 and 1000 ng/ml) were prepared by appropriate dilution from intermediate solutions by mobile phase.

Sample extraction

Aqueous humor or subretinal fluid sample (100 µl) was spiked with 250 ng/ml of IS and 500 µl of acetonitrile added, then mixed on a vortex-mixer vigorously for 90 s and centrifuged at 3000 rpm for 20 min. Upper phase was decanted and evaporated to the dryness under nitrogen flow at 40°C. The residue was reconstituted in 100 µl of mobile phase and 50 µl was injected to the HPLC system.

Method validation

The method was validated according to International Conference on Harmonization (ICH) Guideline for validation of analytical procedures21. The validation parameters were linearity, accuracy, precision, limit of quantitation (LOQ), limit of detection (LOD) and selectivity. To evaluate the performance of the developed method, the acceptance criteria in chromatography for validation parameters were considered. It was not possible to take adequate drug- free human eye layer samples for the validation study because of ethical restrictions. Hence, validation studies were performed using the standard samples prepared in mobile phase.

Linearity

For calibration curves, the peak area ratios of diclofenac to the IS were plotted versus diclofenac concentrations. Linearity was evaluated by standard solutions containing 20, 50, 100, 200, 400, 600, 800 and 1000 ng/ml (n=8) of diclofenac in mobile phase. A calibration curve was prepared at each analysis day for seven days, and the regression equation and correlation coefficient were determined.

Accuracy and precision

To evaluate accuracy and precision, standard solutions at three concentration levels (50, 200 and 800 ng/ml)

in the calibration range were analyzed. To determine the intra-day and inter-day accuracy and precision, samples were independently prepared and analyzed six times in the same day and on six different days.

Precision and accuracy were calculated as relative standard deviation (RSD %) and percentage deviation of obtained concentration from added concentration (bias %), respectively.

Sensitivity (LOD and LOQ)

The limits of detection and quantitation were determined as the sensitivity of the developed method.

The LOD was decided as the diclofenac concentration giving a ratio of signal to noise equal to three (S/N=3).

The LOQ was the lowest diclofenac concentration of calibration curve with RSD value of < 15%.

Selectivity

The selectivity was described as the ability of the method to resolve diclofenac from baseline and other peaks. The specificity was determined for the HPLC method in order to verify that diclofenac does not interfere with any of the matrices composing the eye layers. For these studies, the chromatograms of aqueous humor and subretinal fluid and their drug- free sample solutions were compared.

Recovery

In order to establish the reliability and suitability of the proposed methods, recovery experiments were carried out. For absolute recovery, known amounts of diclofenac (200 ng/ml) and IS (250 ng/ml) were added to water, and the mixtures were analyzed by the proposed method (n=6). For relative recovery, drug-free samples were spiked with 400 ng/ml of diclofenac and 250 ng/ml of IS, and the mixtures were analyzed by the proposed method (n=3).

Application of developed method to the eye samples

The eye samples, aqueous humor and subretinal fluids, were obtained from patients administered Voltaren® (0.1% diclofenac sodium) eye drops before

(4)

retina decollement surgery. Patients were instilled three times with 15 min intervals one night before surgery and four times with 15 min intervals on the day of surgery. Aqueous humor and subretinal fluids were collected during surgery, stored at –25°C till analysis and protected from light. The analysis of the samples was performed by the method developed and validated in this study.

The local ethical committee of Ankara Hospital approved this study, and written informed consent was taken from all patients accepted into the study.

RESULTS AND DISCUSSION

Chromatographic conditions and parameters

Chromatographic conditions were optimized by changing the ratio of acetonitrile, flow rate, pH and working potential. The best resolution with the best peak shape and low retention time were obtained by a mobile phase consisting of acetonitrile (containing 0.065% triethylamine) and 1.65% glacial acetic acid (50:50, v/v) (pH: 4.30) at a flow rate of 1.0 ml/min, and the working potential was set to 1000 mV at electrochemical detector. Under the described chromatographic conditions, diclofenac and quinine (IS) were well separated from baseline and each other (Figs. 1, 2). Retention times for diclofenac and IS were 14.74±0.02 (RSD=0.99%, n=10) min and 3.86±0.02 (RSD=1.08%, n=10) min, respectively. The relative retention time of diclofenac/quinine was 3.81±0.02 (RSD=1.05%, n=10). Inter-day and intra-day variations of diclofenac and quinine (IS) retention times were less than 1.08%. For both compounds, sharp and symmetric peaks were obtained with a good baseline resolution (Rs: 15.89) and minimal tailing (symmetry factors: 0.94 and 0.98, respectively), thus facilitating the accurate measurement of the peak area.

Method validation Linearity

The method was linear in the range of 20 - 1000 ng/ml diclofenac containing quinine as an IS at 250 ng/ml (Table 1, r = 0.9998±0.0003, n = 7). The equation

of regression obtained was y = 12.07x + 0.02, and the mean determination coefficient of seven consecutive calibration curves was r2 = 0.9996±0.0005.

Accuracy and precision

The accuracy and precision were investigated at three concentration levels of diclofenac in the linear range with six independent replicates on the same day and on six consecutive days. The intra-day and inter-day bias values were found to be less than 1.72 and 1.14%, and the intra-day and inter-day RSD values were not higher than 2.19 and 1.94%, respectively (Table 2).

Table 1. The analytical characteristics of proposed method (n = 7)

y = bx + a; x: concentration, y: peak area ratio, b: slope, a: intercept LOD: Limit of detection. LOQ: Limit of quantitation.

Table 2. Accuracy and precision assay data of diclofenac determination (n = 6)

aFound:x = mean ± standard error.

bPrecision: RSD % = Relative standard deviation %.

cAccuracy: Bias % = [|(Founded - Added)|/ Added] x 100.

(5)

Sensitivity

The LOD, defined as three times the level of the baseline noise, was 10 ng/ml for diclofenac, and the LOQ, defined as the lowest concentration at the calibration curve, was 20 ng/ml, with a RSD value of 7.11% (n = 7).

Selectivity

Diclofenac and IS were well resolved from baseline and each other with an acceptable resolution value much higher than 1.5 (Fig. 1a, 2a). The comparison of the chromatograms of drug-free and diclofenac- spiked aqueous humor samples demonstrated that there was no interfering peak from matrix (Fig. 1b, 1c). The same behavior was obtained from drug-free and diclofenac-spiked subretinal fluids, suggesting that there was also no interfering peak from matrix (Fig. 2b, 2c). These results indicated that the method presented in this study was selective and specific.

Recovery

While the relative recovery was 97.76±2.11 % (n=3), the absolute recovery was found to be 99.51±1.26%

(n=6). The relative recovery could not be repeated more than three times because of the lack of drug- free eye fluid due to ethical considerations.

Application to the eye samples

The eye samples, aqueous humor and subretinal fluids, were obtained from patients topically administered diclofenac before retina décollement surgery. The determination of diclofenac levels in these eye samples was successfully performed by the method presented in this study. The concentration in aqueous humor ranged from 5.84 to 10.49 ng/ml (n=5), while diclofenac concentration in subretinal fluid was 13.81 and 80.69 ng/ml (n=2).

Figure 1.Representative chromatograms of (a) diclofenac standard solution (100 ng/ml), (b) drug-free aqueous humor and (c) diclofenac spiked (100 ng/ml) aqueous humor samples [IS: Internal Standard (Quinine, 250 ng/ml). D:

a)

b)

c)

IS IS IS

D

D

Figure 2.Representative chromatograms of (a) diclofenac standard solution (100 ng/ml), (b) drug-free subretinal fluid and (c) diclofenac spiked (100 ng/ml) subretinal fluid samples [IS: Internal standard (Quinine, 250 ng/ml). D: Diclofenac]

c)

IS b)

IS a)

IS D

D

(6)

CONCLUSION

In this study, a simple, fast, efficient and reliable HPLC-ECD method was developed and validated for the analysis of diclofenac in subretinal fluids and aqueous humor. The method presented in this study was selective enough using a conventional RP18 analytical column and applicable to subretinal and aqueous humor samples obtained from patients after simple protein denaturation with acetonitrile. Thus, the developed method is recommended for clinical investigations based on determination of diclofenac levels in subretinal and aqueous humor fluid after its topical administration in view of its high recovery, precision and accuracy.

REFERENCES

Scholer DW, Boettcher ECK, Schweizer A.

Pharmacology of diclofenac sodium, The Am. J.

Med., 80 (4), 34-38, 1986.

Juhlin T, Björkman S, Gunnarsson B, Fyge Å, Roth B, Höglund P. Acute administration of diclofenac, but possibly not long term low dose aspirin, causes detrimental renal effects in heart failure patients treated with ACE-inhibitors, Eur.

J. Heart Fail, 6 (7), 909-916, 2004.

Bajaj P, Ballary CC, Dongre NA, Baliga VP, Desai AA. Comparison of the effects of parecoxib and diclofenac in preemptive analgesia: a prospective, randomized, assessor-blind, single-dose, parallel- group study in patients undergoing elective general surgery, Curr. Ther. Res., 65 (5), 383-397, 2004.

Daglar B, Kocoglu H, Celkan MA, Goksu S, Kazaz H, Kayiran C. Comparison of the effects of lornoxicam versus diclofenac in pain management after cardiac surgery: a single-blind, randomized, active-controlled study, Curr. Ther.

Res., 66 (2), 107-116, 2005.

Cleuvers M. Mixture toxicity of the anti- inflammatory drugs diclofenac, ibuprofen, naproxen, and acetylsalicylic acid, Ecotoxicol Environ Saf., 59 (3), 309-315, 2004.

Hsu JKW, Johnston WT, Read RW, McDonnell PJ, Pangalinan R, Rao N, Smith RE. Histopathology

of corneal melting associated with diclofenac use after refractive surgery, J. Cataract Refract Surg., 29 (2), 250-256, 2003.

Baydoun L, Müller-Goymann CC. Influence of n-octenylsuccinate starch on in vitro permeation of sodium diclofenac across excised porcine cornea in comparison to Voltaren ophtha, Eur. J.

Pharm. Biopharm., 56 (1), 73-79, 2003.

O’Brien TP, Li QJ, Sauerburger F, Reviglio VE, Rana T, Ashraf MF. The role of matrix metalloproteinases in ulcerative keratolysis associated with perioperative diclofenac use, Ophthalmology, 108 (4), 656-659, 2001.

Weigel S, Kallenborn R, Hühnerfuss H.

Simultaneous solid-phase extraction of acidic, neutral and basic pharmaceuticals from aqueous samples at ambient (neutral) pH and their determination by gas chromatography–mass spectrometry, J. Chromatogr. A, 1023 (2), 183-195, 2004.

Blum W, Faigle JW, Pfaar U, Sallmann A.

Characterization of a novel diclofenac metabolite in human urine by capillary gas chromatography- negative chemical ionization mass spectrometry, J. Chromatogr. B, 685 (2), 251-263, 1996.

Sioufi A, Pommier F, Godbillon J. Determination of diclofenac in plasma and urine by capillary gas chromatography—mass spectrometry with possible simultaneous determination of deuterium-labelled diclofenac, J. Chromatogr., 571 (1-2), 87-100, 1991.

Schneider W, Degen PH. Simultaneous determination of diclofenac sodium and its metabolites in plasma by capillary column gas chromatography with electron-capture detection, J. Chromatogr. B, 383, 412-418, 1986.

Kadowaki H, Shiino M, Kobayashi IUK. Sensitive method for the determination of diclofenac in human plasma by gas chromatography-mass spectrometry, J. Chromatogr., Biomedical Applications, 308, 329-333, 1984.

Schneider W, Degen PH. Simultaneous determination of diclofenac sodium and its hydroxy metabolites by capillary column gas chromatography with electron-capture detection, J. Chromatogr., 217, 263-271, 1981.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

(7)

Schweizer JA, Willis V, Jack DB, Kendall MJ.

Determination of total monohydroxylated metabolites of diclofenac in urine by electron- capture gas-liquid chromatography, J. Chromatogr.

A, 195 (3), 421-424, 1980.

Ikeda M, Kawase M, Hiramatsu M, Hirota K, Ohmori S. Improved gas chromatographic method of determining diclofenac in plasma, J.

Chromatogr. B, 183 (1), 41-47, 1980.

Dorado P, Berecz R, Cáceres MC, Lerena A.

Analysis of diclofenac and its metabolites by high-performance liquid chromatography:

relevance of CYP2C9 genotypes in diclofenac urinary metabolic ratios, J. Chromatogr. B, 789 (2), 437-442, 2003.

Roskar R, Kmetec V. Liquid chromatographic determination of diclofenac in human synovial fluid, J. Chromatogr. B, 788, 57–64, 2003.

Kuhlmann O, Krauss G. Crocheted ETFE-reactor for on-line post-column photoderivatization of diclofenac in high-performance liquid chromatography, J. Pharm. Biomed. Anal., 16, 553–559, 1997.

Kuhlmann O, Stoldt G, Struck H, Krauss G.

Simultaneous determination of diclofenac and oxybuprocaine in human aqueous humor with HPLC and electrochemical detection, J. Pharm.

Biomed. Anal., 17, 1351–1356, 1998.

ICH Harmonized Tripartite Guideline, Validation of analytical procedures: Text and Methodology Q2(RI), ICH Steering Committee, 2005.

15.

16.

17.

18.

19.

20.

21.

Referanslar

Benzer Belgeler

15 Table 3: Composition of the Alkalie Cd-dithizone (-Deriphat) Test Solutions Used.19 Table 4: Different Cd 2+ Concentrations with Constant Dithizone and NaOH

從小在加拿大生活,四歲在 Jean Lyons School of Music 現任校長 Susan Wong Lim 的指導下踏入了鋼琴的世界,六歲

請每月併健保醫療費用向中央健保局各分局申請,採代收代付之原則辦理,並依全民健康保險醫事服務機構醫療服務審查

In this article, a new compact dual-mode loop resonator designed by loading interdigital capacitors and short-circuited stubs is proposed.. The interdigital capacitors and

The standard solution of different concentrations of mefenamic acid was measured for absorbance at 350 nm and linear calibration curves were obtained that obeyed Beer’s

Objectives: In this work, a simple and rapid liquid chromatographic method for the simultaneous determination of irbesartan (IRBE) and hydrochlorothiazide (HCT)

No method reported previously estimation of triamcinolone in human blank plasma by using the protein precipitation (PPT) extraction in the literature.. The present work was

A simple, rapid and reliable high performance liquid chromatography method (HPLC) with ultraviolet detection (UV) was developed and validated according to