1 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Tip kodu BLCDP-4M12MT-8XSG-PD

İdent no. 6811168

Nominal system voltage 24 VDC

System power supply yedek güç ile

Voltage supply connection 2 x M12, 5 pimli

Admissible range Vi 18…30VDC

Nominal current Vi 200 mA

Max. current Vi 1 A

Admissible range Vo 18…30VDC

Nominal current Vo 100 mA

Max. current Vo 4 A

Electrical isolation 8 × SG I/O kartları, serbest biçimde seçilebilir diji- tal kanalları nedeniyle çalışma ve yük gerilimi için ortak bir referans potansiyeline sahiptir. Daha son- ra, bu cihazda yer alan tüm gerilim kaynakları (VI, VO, V+) eş zamanlı olarak uygun güç kaynaklarına bağlanmalıdır.

Fieldbus iletim hızı 9.6 kbps …12 Mbps

Ayar iletim hızı Otomatik algılama

Fieldbus adres aralığı 0...99

Fieldbus adresleme 2 dec. Rotary coding switches

Fieldbus bağlantı teknolojisi 2 × M12

5-pin, reverse-keyed

Fieldbus sonlandırma External

Servis arayüzü RS232 interface

Digital inputs from 8XSG

Input type PNP

Type of input diagnostics Channel diagnostics

Sensor supply (VSENS) 24 VDC, 100 mA short-circuit limiting Düşük seviye sinyal gerilimi < 4.5 VDC

Yüksek seviye sinyal gerilimi 7…30 VDC

Düşük seviye sinyal akımı < 1.5 mA

Yüksek seviye sinyal akımı 2.1 … 3.7 mA

Giriş gecikmesi (configurable) 0.25 or 2.5 ms

On-Machine™ kompakt fieldbus I/O blo- kları

PROFIBUS-DP slave

9.6 kbps … 12 Mbps

Two 5-pin, reverse-keyed M12 male re- ceptacles for fieldbus connection

2 rotary coding switches for node-ad- dress

IP 69K

M12 I/O ports

LEDs indicating status and diagnostics

Electronics galvanically isolated from the field level via optocouplers

8 digital PNP channels, 24 VDC

Max. 0.5 A per channel

Channel diagnostics

Adjustable filter times (input delay)

Input inverting possible

8 configurable digital channels

24 VDC, PNP

Max. 0.5 A

Channel diagnostics

Adjustable filter times

Invertible inputs

(2)

Ausgabe • 2020-11-14T12:39:19+01:00

2 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Digital outputs from 8XSG

Output type PNP

Type of output diagnostics Channel diagnostics

Sensor supply (VSENS) 24 VDC from supply voltage

Kanal başına çıkış akımı 0.5 A

Çıkış voltajı 24 VDC from supply voltage

Çıkış gecikmesi 3 ms

Yük tipi Resistive, inductive, lamp load

Yük direnci, dirençli > 48 ò

Yük direnci, endüktif < 1.2 H

Lamba yükü < 3 W

Anahtarlama frekansı, dirençli < 200 Hz Anahtarlama frekansı, endüktif < 2 Hz Anahtarlama frekansı, lamba yükü < 20 Hz

Kısa devre koruması evet

Boyutlar 113 x 71 x 32.5mm

Mounting 2 × 5,4 mm delik çapları, 1,7 Nm tork

Ağırlık 390 ± 20 g

Housing material Glass fiber reinforced nylon, nickel-plated connector

Muhafaza rengi siyah

Window material Lexan

Material screw nikel kaplamalı pirinç

Material label Polikarbonat kaplamalı polyester

Zemin etiketi malzemesi Nickel-plated brass

IP Derecesi IP67

IP69K

Çalışma sıcaklığı -40…+70 ºC

Saklama sıcaklığı -40…+85 ºC

Bağıl nem 15 to 95% (non-condensing)

Titreşim testi acc. to IEC 61131-2

Extended vibration resistance

- up to 20 g (at 10 up to 150 Hz) For mounting on base plate or machinery

Darbe testi acc. to IEC 61131-2

Elektromanyetik uyumluluk acc. to IEC 61131-2

Onaylar CE, cULus

(3)

Ausgabe • 2020-11-14T12:39:19+01:00

3 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com PROFIBUS-DP

Fieldbus cable (example): RSSW RKSW 455-2M ident-no. U0350 or RSSW-RKSW455-2M ident-no. 6602222

Digital Inputs and Outputs

Extension cable (example): RK 4.4T-2-RS 4.4T ident-no. U2445 or RKC4.4T-2-RSC4.4T/TEL ident-no. 6625208

Tel ataması

Auxiliary Power

Extension cable (example): RKC 4.4T-2-RSC 4.4T ident-no.

U5264 or RKC4.4T-2-RSC4.4T/TEL ident-no. 6625208

Tel ataması

(4)

Ausgabe • 2020-11-14T12:39:19+01:00

4 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com Status: Station LED

LED Color Status Description

IO'lar KAPALI Güç kapalı

KIRMIZI AÇIK Yetersiz güç beslemesi

KIRMIZI YANIP SÖNÜYOR (1Hz) Sapma istasyonu konfigürasyonu KIRMIZI YANIP SÖNÜYOR (4 Hz) Modül veri yolu iletişimi yok

YEŞİL AÇIK İstasyon TAMAM

YEŞİL YANI SÖNÜYOR Kuvvet modu etkin

OFF Keine Feldbus Kommunikation

GREEN ON Feldbus Kommunikation aktiv

GREEN FLASHING (1 Hz) No field bus communication active, device status OK

RED ON Bus error at the gateway; no data exchange

BUS

RED FLASHING Faulty PROFIBUS-DP address

OFF Keine Feldbus Kommunikation

GREEN ON Feldbus Kommunikation aktiv

GREEN FLASHING (1 Hz) Keine Feldbuskommunikation aktiv, Gerätestatus OK

RED ON Busfehler am Gateway; kein Datenaustausch

BUS

RED FLASHING Fehlerhafte PROFIBUS-DP Adresse

Status: I/O LED

LED Color Status Description

D * OFF Diagnostic disabled

RED ON Station / module bus communication failure

RED FLASHING (0.5Hz) Summarized diagnostic

XSG channels 0…7

OFF Status channel x = 0 (OFF),

diagnostic disabled

GREEN ON Status channel = 1 (ON)

RED ON Short-circuit at output

RED FLASHING (2 Hz) Short-circuit sensor supply

* D LED also indicates gateway diagnostic

(5)

Ausgabe • 2020-11-14T12:39:19+01:00

5 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com I/O Data Map

INPUT BYTE Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0

0 DI 17 DI 16 DI 15 DI 14 DI 13 DI 12 DI 11 DI 10

1 - - - -

OUTPUT BYTE Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0

0 DO 17 DO 16 DO 15 DO 14 DO 13 DO 12 DO 11 DO 10

1 - - - -

Referanslar

Benzer Belgeler

25 Şubat AB, Rusya Devlet Başkanı Vladimir Putin ve Dışişleri Bakanı Sergey Lavrov’u yaptırım listesine aldı.. 25 Şubat Rusya, Ukrayna’ya saldırısını

YUKARI ve AŞAĞI ok tuşlarını kullanarak set point (ayar değeri) değerini seçin ve ENTER tuşuna basarak onaylayın. ESC tuşuna basıldığında, önceki değer

25 Mart Ukrayna Savunma Bakanlığı 24 Şubat’ta müdahalenin başlamasından bu yana Rusya’nın Ukrayna’ya 467 füze de dahil olmak üzere 1.804 hava saldırısı

0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com Ethernet/IP. Adresleme EtherNet/IP teknik

GREEN FLASHING (1Hz) Fieldbus communication disabled, device status OK. RED ON

Bir elektrik kesintisi durumunda motor, fabrikada ayarlanmış olan 2 saniyelik köprüleme süresini (PF) dikkate alarak, daha önce seçilmiş olan acil durum pozisyonuna ulaşılmasını

Ürün ortamı yüzeyine olan mesafe yanlış (çok büyük) verildiğinde, gerçek dolum durumu hatalı sinyal olarak görüleceğinden kayda alına- cağından bu mesafeyi kontrol edin.

Yüksek seviye sinyal gerilimi &gt; 11 V Düşük seviye sinyal akımı &lt; 1,5 mA Yüksek seviye sinyal akımı &gt; 2 mA. Type of input diagnostics