• Sonuç bulunamadı

Single Mode : Open lock with one (1) code (Manager or User Code).

Dual Mode : Open lock with two (2) codes (Manager and User Code).

38

SET / CHANGE TIME DELAY & TIME WINDOW MODE

• Enter the master code and hold down last digit of code until one beep sounds, followed by two beeps.

• Push “9”.

• Enter a six (6) digit number in the range of 001001 - 040020. The first 3 digits are for the Time Delay and the second 3 digits are for the Time Window. The maximum Time Delay is forty (40) minutes, and the maximum Time Window is twenty (20) minutes. For example, to set a fifteen (15) minute Time Delay and a three (3) minute Time Window, enter 015003.

Note: Time Delay can not be set with Master Code. If enterthe master code, the controller will always unlock immediately.

SINGLE USER MODE

• Enter user or manager code. One beep followed by four beeps sound indicates the controller starts Time Delay period.

• The entry pad signals one beep every ten (10) seconds followed by four beeps at the end of Time Delay period indicating the start of the Time Window period.

• Re-enter user or manager code to unlock.

Note:

- When unlocking by master code, the controller is unlocked without time delay and time window.

- During the time window if the code is not entered again, the controller will lock after time window period.

DUAL USER MODE

• Enter user / manager codes. After 10 seconds enter manager / user codes. One beep followed by four beeps indicates that the controller starts the Time Delay period.

• The entry pad signals one beep every ten (10) seconds followed by four beeps at the end of the Time Delay period indicating the start of the Time Window period.

• Re-enter user and manager /manager and user codes to unlock.

Note:

• When unlocking by master code, the controller is unlocked without time delay and time window.

• During the time window if the codes are not entered again, the controller will lock after time window period.

37

SINGLE USER MODE

• Enter the master code and hold down last digit of code until one beep sounds, followed by two beeps.

• Push “0” to set controller to single user mode.

• Enter the manager or user code to open the lock.

DUAL USER MODE (Manager & User Code to Unlock)

• Enter the master code and hold down last digit of code until one beep sounds, followed by two beeps.

• Push “8” to set controller to dual user mode.

Note:

- Make it sure that the manager and user codes are both set and enabled before setting Dual User Mode.

- After setting Dual User Mode, manager code can not set functions of user code, such as disabling or deleting.

- In Dual User Mode, when master code deletes codes, the manager code and user code will be both deleted and single user mode is set.

- In Dual User Mode, master code disables / enables manager code and user code at the same time.

TIME DELAY AND TIME WINDOW

Time Delay : A time period of waiting for the lock to open. The maximum Time Delay is forty (40) minutes.

Time Window : A time period for entering the code(s) to open lock after Time Delay.

The maximum Time Window is twenty (20) minutes.

OPEN LOCK

• Enter user or manager code.

• The lock signals one beep and opens.

SINGLE AND DUAL USER MODE

Single Mode : Open lock with one (1) code (Manager or User Code).

Dual Mode : Open lock with two (2) codes (Manager and User Code).

WRONG ENTRY PENALTY

Entry of four (4) consecutive invalid codes results in a 5-minute delay period.

• The unit beeps in 5 second intervals.

• During delay period, if batteries are removed, the controller stops counting time;

if batteries are reinstalled, the entry pad continues to count down until 5 minute delay period is completed.

STANDBY MODE

The controller will switch to standby mode after a long beep sounds if there is no operation within 10 seconds after the system is activated.

AUTOMATIC RE-LOCK

The controller will automatically re-lock in 4 seconds after a valid entry is made and the door is opened.

LOW BATTERY ALERT

• Repeated beeping from the controller during an unlocking indicates that the battery is low and needs immediate replacement.

• Manufacturer recommends using DuracellTM or Energizer® Alkaline batteries and annually replacing them.

CODE FEATURES Super Code

• Opens lock

• Set functions

• Manufacturer default 1-1-1-1-1-1.

• Resets controller back to manufacturer's default settings.

Manager Code

• Opens lock

• Set functions

• Manufacturer default 1-2-3-4-5-6.

User Code

• Opens lock

• No default setting and needs to be set by end-user before operating lock.

CHANGE SUPER CODE

Enter the default code, 1-1-1-1-1-1. When the LCD screen shows “Select Menu”, press or and select “Change Code”. Press “Menu/OK” press or and select ''New code'' enter a new code (6 digits). Repeat the same code again (6 digits). LCD screen shows ''Code Saved'' The first code with ID No. 00 is changed successfully.

Note:

- When user enters a code, if a wrong digit is entered, push “Back ” button to re-enter. When a code is entered, the display will show the last digit entered.

- Always change the manufacturer's default supercode before the product leaves from your hand.

39

WRONG ENTRY PENALTY

Entry of four (4) consecutive invalid codes results in a 5-minute delay period.

• The unit beeps in 5 second intervals.

• During delay period, if batteries are removed, the controller stops counting time;

if batteries are reinstalled, the entry pad continues to count down until 5 minute delay period is completed.

STANDBY MODE

The controller will switch to standby mode after a long beep sounds if there is no operation within 10 seconds after the system is activated.

AUTOMATIC RE-LOCK

The controller will automatically re-lock in 4 seconds after a valid entry is made and the door is opened.

LOW BATTERY ALERT

• Repeated beeping from the controller during an unlocking indicates that the battery is low and needs immediate replacement.

• Manufacturer recommends using DuracellTM or Energizer® Alkaline batteries and annually replacing them.

40

CODE FEATURES

Benzer Belgeler