• Sonuç bulunamadı

Functional, clinical and biomechanical comparison of anterior cruciate ligament reconstruction with anatomical placement of transtibial tunnel placement

N/A
N/A
Protected

Academic year: 2021

Share "Functional, clinical and biomechanical comparison of anterior cruciate ligament reconstruction with anatomical placement of transtibial tunnel placement"

Copied!
1
0
0

Yükleniyor.... (view fulltext now)

Tam metin

(1)

1

This open-access article is published and distributed under the Creative Commons Attribution - NonCommercial - No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article without the permission of the Author(s). For reprints and permission queries, please visit SAGE’s Web site at http://www.sagepub.com/journalsPermissions.nav.

Functional, Clinical and Biomechanical Comparison of Anterior Cruciate Ligament

Reconstruction with Anatomical Placement of Transtibial Tunnel Placement

Eray Kılınç1

, Adnan Kara2, Yunus Öç3, Haluk Çelik3, Savaş Çamur4, Osman Tuğrul Eren3

1

Igdir State Hospital, Igdir, TURKEY, 2Istanbul Medipol University, Orthopaedics and Traumatology Department, Istanbul, TURKEY, 3Istanbul Sisli Etfal Education and Research Hospital, Orthopaedics and Traumatology Clinic, Istanbul, TURKEY, 4Agri Dogubeyazit State Hospital, Agri, Istanbul, TURKEY

Objectives: Functional, clinical and biomechanical comparison of Anterior Cruciate Ligament reconstruction with anatomical placement of transtibial tunnel placement.

Methods: 55 patients who can be adequately followed-up being divided into transtibial and anatomic groups. Lachman and Pivot-shift tests were performed to all patients. Laxity was measured by performing KT-1000

arthrometer test with 15,20 and 30 pounds power. Muscle strength were evaluated with Cybex II at 60 ° / sec, 240 ° / sec frequencies with flexion and extension peak torque. The maximum force values of untouched knee and the knee with surgery have been compared. Groups were evaluated by using IKDC knee ligament healing standard form, IKDC activity scale, modified Lysholm and Cincinnati evaluation forms. Return to work and return to fitness times of patients were compared. NCSS 2007 & PASS 2008 Statistical Software was used for statistical analysis. Results: Statistically, there was not any observed significant difference between Lachman and Pivot-shift levels. Positive value of Pivot-shift test and incidence of anterior translation in Lachman test were higher in the cases which were subjected to transtibial technique . There was not any statistically significant difference between Lysholm activity levels of cases. Lysholm activity levels of patients who underwent anatomic techniques significantly higher than transtibial technique. There was not any statistically significant difference between Modified Cincinnati activity levels. Modified Cincinnati activity levels of patients who were subjected anatomical techniques, are significantly higher than transtibial technique. There was not any statistically significant difference between post treatment IKDC activity levels. Intense activity after treatment rate of patient who were subjected to anatomic techniques was significantly higher than transtibial technique. There was a statistically significant differences between Cybex extension-flexion 60 measurements and Extension 240 measurements. Results of KT-1000 arthrometer testing anatomical technique was found to be stable than transtibial technique in antero-posterior translation of the knee kinematics at 20 and 30 pounds of forces. Return to sport times of patients who underwent transtibial technique, significantly higher than anatomic technique. There was not any statistically significant difference between return to work times of patients.

Conclusion: Previously published studies we observed that anatomic single band ACL reconstruction is better than transtibial ACL reconstruction by providing rotational and anterior translational stability control, in reducing the complications and it is more effective in returning normal functions after operation. As an important implication, a single-band anatomic ACL reconstruction’s clinical, functional and laboratory results are found to be better than the transtibial technique.

The Orthopaedic Journal of Sports Medicine, 2(11)(suppl 3) DOI: 10.1177/2325967114S00152

Referanslar

Benzer Belgeler

Fig 9 noise corrupted secret image with noise density=0.7 Fig 10 reconstructed secret image in case 2 Case 3: Consider a fixed amount of salt and pepper noise density of 0.2,

In this project we have developed an “Electronics Concealed Box” which consists of Arduino, RTC (Real Time Clock), RFID Reader, RFID tags(Main Examiner and Invigilator),

In the current paper, the existing edge detection algorithms like Prewitt, Sobel, and Canny were compared to the proposed algorithm called the Luminance edge detection

As in the case of regression based models, errors observed during calibration (five years) of the sophisticated instruments and the errors observed during calibration (five years)

Karotid artere girildikten sonra ortaya çıkan serebral infarktüsün oluşumunda ekstrensek hematom basısı, karotid artere girildiği farkedildikten sonra aşırı manuel

共b兲 Band structures of constituent BN and graphene armchair nanoribbons having 18 atoms in their unit cells and the band structure of the superlattice BN 共18兲/AGNR共18兲

Macaristan’da iki Burley tütün çeşidinde üç yıl boyunca farklı azot dozlarının (0, 4, 8, 12, 16 ve 20 kg/da N) verim, kalite, olgunlaşma oranı, yeşil yaprak verimi,

對於希望接受手術的人而言,最重要的是風險利益的評估,特別是屈光手術這類