• Sonuç bulunamadı

AIM: to check which materials yield OSL, which do not yield OSL and check the behavior of the OSL measurements versus various stimulation parameters. Materials: Aluminum oxide (TLD 500, Al

N/A
N/A
Protected

Academic year: 2021

Share "AIM: to check which materials yield OSL, which do not yield OSL and check the behavior of the OSL measurements versus various stimulation parameters. Materials: Aluminum oxide (TLD 500, Al"

Copied!
3
0
0

Yükleniyor.... (view fulltext now)

Tam metin

(1)

AIM: to check which materials yield OSL, which do not yield OSL and check the behavior of the OSL measurements versus various stimulation parameters.

Materials: Aluminum oxide (TLD 500, Al2O3:C) or Berilium oxide (BeO), AND Lithium fluoride (TLD 100, LiF:Mg,Ti)

PROTOCOL (for all materials): Step 1. Irradiation (1 Gy)

Step 2. TL measurement (350 °C, HR=1 °C/s) after irradiation Step 3. Irradiation (1 Gy)

Step 4. Continuous Wave OSL (Room temperature, 90% intensity, 100 s) Step 5. TL measurement (350 °C, HR=1 °C/s) after OSL.

Step 6. Repeat steps 3-5 for various measurement temperatures (40 °C, 50 °C, 60 °C, 70 °C, 80 °C, 90 °C and 100 °C).

Step 7, Repeat steps 3-5 for various stimulation intensities (80%, 70%, 60%, 50%, 40%, 30% and 20 %).

Step 8. Repeat steps 3-5 for another OSL measurement time 200 s.

Analysis:

1. Check which materials give OSL signal and which do not.

2. Check the dependence on the stimulation temperature by plotting a figure similar to Fig 2.

3. Check the dependence on the stimulation intensity by plotting a figure similar to Fig 3.

4. 4. Check the impact to the TL glow curve intensity

(2)

Experimental CW-OSL Curves

 Experimental parameters 1. Illumination t (sec) 2. Pstimulation(mW/cm2) 3. Tmeasurement(oC) 4. Tpreheat(oC) 5. Preheat t (sec)  Dependent Variables 1. Imax(a.u.) 2. σ (cm2)

0

20

40

0

1500

3000

4500

6000

C W O S L ( a .u .)

illumination time (sec)

Quartz

Fig. 1: Experimental parameters and dependent variables in CW-OSL measurements.

(3)

Fig. 3: CW-OSL for various stimulation intensities.

Referanslar

Benzer Belgeler

materyali için sabit ısıtma hızında TL ölçümlerini gerçekleştiriniz:

AMAÇ: OSL sinyali veren ve vermeyen materyallerin incelenmesi ve çeşitli uyarma parametrelerine göre OSL ölçümlerinin davranışlarının incelenmesi.. Materyaller: Alüminyum

parametreye göre grafiğinin çizilmesi. Her bir durum için, ana OSL bileşeninin foto-iyonizasyon tesir kesitinin hesaplanması. LM- OSL ölçümlerinin TL ışıma

Check sensitivity and sensitization: Measure TL for one heating rate according to the following protocol (material TLD

AIM: To check the different shape of the glow curves of each material and to assess the number of peaks present.. Irradiation (0.5 Gy for synthetic materials, 15 Gy for

AIM: to get familiar with the Linearly Modulated OSL (LM-OSL) signal and check the behavior of the LM-OSL measurements versus various stimulation parameters. Check the shape of

Examples of LM-OSL curves Photo-ionization cross section Stimulation intensity flux: Linear (LM-OSL) 1-b 2 u td u y I d   CW-OSL curves Pseudo LM-OSL (PS LM-OSL)..

Pulsed OSL (P-OSL): the sample is exposed to stimulation pulses, while monitoring of the signal takes place when stimulation mode is off (NO FILTERS