HT-34 LIFT CONTROLCARD

www.heytech.com.tr

EN81-1/2

ﺔ���ﻌﻟا

(2)
(3)

Kullanım Kılavuzu User Manual

Инструкция По Эксплуатации Manual De Utilizare

Manual De Usuario Manuel D'utilisation Manual Do Usuário

ﺔ���ﻌﻟا

1 13 25 37 49

İÇİNDEKİLER

index / содержание / conținut / contenido contenu / conteúdo / تايوتحلما

Drawings

(4)

Türkçe

• Tek hız,Çift hız,Vvvf çalışma

• Dublex çalışma

• Akıllı backligt

• 8 farklı dil desteği

• Şifre koruması

• Kurtarma modu

• Ding dong çıkışı

• 16 durak karışık ve basit kumanda

• 8 durak aşağı toplama

• 16 durak aşağı toplama (seri kart ile)

• 8 durak çift buton (seri kart ile)

• Dahili akü şarj (seri kart üzerinde)

• Yön okları Flash özelliği dururken ve giderken ayrı ayarlar

• 2-satır 16-karakter LCD ekran ve 4-tuş klavye

• Kabin ile seri tesisat bağlantısı

• Dahili faz sıralı motor koruma devresi

• İki otomatik kapı için dahili kontrol giriş ve çıkışları

• Kısa devre korumalı dijital ve sinyal çıkışları

• 7-segment, Gray kod, Gray+1 kod,Bınary kod, Bınary+1 kod, Katta çıkış seçeneği

Boy-En-Yükseklik (mm) Koruma Sınıfı Çalışma Sıcaklığı Şebeke Kontrol Girişleri Kontrol Beslemesi Gerilimi Güç harcaması max.

Güvenlik Devre Gerilimi Kontrol Sinyal Girişi Kontrol Sinyal Çıkışı

1-HT-34 GENEL ÖZELLİKLERİ

2-HT-34 TEKNİK ÖZELLİKLERİ

3-TUŞ TAKIMI ÖZELLİKLERİ

285-85-20 IP20

±0- +60 °C 3 x 380V, 50Hz, N 24 ± 5 Vdc 400mA 10W, 24V için 230Vac

24 ± 5 Vdc 24 ± 5 Vdc

Tuş takımı üzerinden rahatça menü ayarlanabilir hata kayıtları görülebilir istenilen durağa kayıt verilebilir asansör gözlemlenebilir.

(5)

Türkçe

• Menü ye giriş: Enter tuşuna basarak menü ye giriniz.

• Menüden çıkış: Esc tuşu ve ardından Enter tuşuna basarak menüden çıkınız.

• Manuel harekete giriş: Esc tuşuna 3 sn basarak kart üzerinden revizyon hareket e giriniz

• Menü içinde hareket: Aşağı yukarı ok tuşları ile menü içerisinde hareket.

ESC DWN UP ENT

HEYTECH HT-34 Kumanda kartı tahrik tipi halatlı Asansörler için tasarlanmış EN81-1/2 standartlarına uygun tümleşik, elektronik bir kontrol kartıdır.Kul- lanıcılar kontrol kartının programlarını kullandıkları kumanda ve asansör sistemine göre tuş takımı yardımı LCD ekrandan görerek yapabilirler.

Çift otomatik kapı için dahili kapı röleleri bulunmaktadır.

Dahili faz kontrol devresi bulunmaktadır.

Asansör sisteminin EN81-1/2 standartlarına elektriksel olarak uygun olması için,

• Kumanda kartının, kumanda panosunun elektrik bağlantılarının uygun olması gerekir.

• Kesinlikle topraklama hattının var olduğunu kontrol ediniz. Özellikle kumanda tablosu, motor gövdesini, tüm emniyet tertibatını, kabin ve süspansiyonunu topraklama hattını bağlayınız.

• Kumanda kartının enerjisini kesmeden cam muhafazasını çıkarmayınız.

• Uzun yıllar çalışmadan dolayı oluşabilecek toz, kir, yağlanma ve paslanmalar emniyet devrelerinin sağlıklı çalışmasına engel teşkil edebilir. Periyodik bakımlar esnasında gereken temizlik yapılmalıdır.

• Makine motorunuzda mekanik fren swiçleri varsa bağlayınız.

Bu belge kullanıcılar için bilgilendirme amacı ile düzenlenmiştir.

HEYTECH gerekli gördüğü durumlarda dökümanın içeriğinde değişiklik yapabilir.

4-GÜVENLİK NOTLARI

(6)

Türkçe

R, S, T MP 10A 120 130 140 A15 A3 A5 LIR LRO RP0 RP 1 2 S1A S1B 11 RU2 RU1 RH RF 100 1000 870 KRC

KAK CM SAK

2Şebeke besleme girişleri Şebeke nötr

Güvenlik Devresi Nötr Dönüşü / Kontaktörlerin Nötr Çıkışı Stop Devresi

Kapı Fiş Kontak Devresi Kapı Kilit Devresi A Kapı Sinyal Ortağı A Kapı Kapa Sinyal Çıkışı A Kapı Aç Sinyal Çıkışı

Kapı Açma Magneti Röle Kontak Ortağı Kapı Açma Magneti Röle Kontak Açığı Ana Kontaktörlerin (RPA, RPB) Besleme Gerilimi Ana Kontaktörler (RPO RPA)

Kabin Faz Girişi Kabin Lamba Çıkışı Seri Habaerleşme A Kanalı Seri Habaerleşme B Kanalı RU1-RU2-RH-RF Ortağı Yukarı Yön Kontaktör Çıkışı Aşağı Yön Kontaktör Çıkışı Yüksek Hız Röle Çıkışı Düşük Hız Röle Çıkışı Kart Besleme Girişi (+24v dc) Kart Besleme Girişi (-24v dc) Pano Revizyon Sİnyali

Ana kontaktörlerin geri besleme girişi. 100 sinyali ana kontaktörlerin kapalı kontaklarından seri geçirilerek bu girişe bağlanmalıdır.

Kurtarma kontaktör beslemesi SAK KAK ortağı

Şebeke kontaktör beslemesi

5-HT-34 Kumanda Kartı Üzerindeki Rumuzlar

(7)

Türkçe K16

K19 K20 DTS PTC 817 818 M1 142 500 501 869 804 YAN DEP SA SB A,B,C, X01,X16 031 032 02 01 12

Kapı Aç limit Sinyali

Kapı Kapama Limiti Sinyal Girişi Kapı Aç Butonu,Fotosel Sinyal Girişi Kapı Kapa Butonu Sinyal Girişi

Motor Termistörü & Pano Termostatı & Fren Direnci Termostatı Kuyu Alt Zorunlu Yavaşlatıcı

Kuyu Üst Zorunlu Yavaşlatıcı Manyetik Bistabil Şalter Girişi Manyetik Bistabil Şalter Girişi Revizyonda Aşağı Yön Sinyal Girişi Revizyon Yukarı Yön Sinyal Girişi Revizyon Anahtarı (Kabin üstü el terminali) Aşırı Yük Sinyal Girişi

Yangın Aktif Sinyal Girişi +24v dc Deprem Aktif Sinyal Girişi +24v dc Seri Haberleşme A Kanalı Seri Haberleşme B Kanalı

7 Segment Dijital Çıkışlar ( Gray ,Bınary çıkışları menüden seçilir) Çağrı sinyal girişleri

Aşağı Ok Sinyal Çıkışı Yukarı Ok Sinyal Çıkışı Servis Dışı Sinyal Çıkışı Aşırı Yük Lamba Çıkışı Meşgul sinyal çıkışı

6-HT-34 SERİ KARTI RUMUZLARI

SA SB 1000 100 2

Seri Haberleşme A Kanalı Seri Haberleşme B Kanalı Kart Besleme Girişi (-) Kart Besleme Girişi (+) Kabin Lamba Çıkışı

(8)

Türkçe 1 K3 K5 K15 K16 K19 X01...X16 DD

A, B,C,D,E,F,G,2G 32

31 02 01 500 501 804 VAT K20 DTS HP, HP AB AA A+

A- -12 +12

Kabin Faz Girişi Kapı Kapa Sinyal Çıkışı Kapı Aç Sinyal Çıkışı Kapı Sinyal Ortağı Girişi Kapı Aç limit Sinyali Kapı Kapama Limit Sinyali Kabin içi buton girişleri Katta Sinyal Çıkışı 7 Segment Dijital Çıkışlar Yukarı Ok Sinyal Çıkışı Aşağı Ok Sinyal Çıkışı Servis Dışı Sinyal Çıkışı Aşırı Yük Lamba Çıkışı

Revizyonda Aşağı Yön Sinyal Girişi Revizyon Yukarı Yön Sinyal Girişi Aşırı Yük Sinyal Girişi Vatman Sinyal Girişi

Kapı Aç Butonu,Fotosel Sinyal Girişi Kapı Kapa Butonu Sinyal Girişi Hoparlör Çıkışı

Alarm Sinyal Girişi (+12V) Acil Aydınlatma Lamba Çıkışı (+12V) Akü + Girişi

Akü - Girişi 12V - Çıkışı 12V + Çıkışı

(9)

Türkçe

00-Kabin Seri Kart 01-Durak Sayısı 02-Kapı Tipi 03-Oto Kapı Katta 04-Oto Kapı Park ta 05-Tek Kapı tam Oto 06-Kapı Özel Ayarı 07-Asansör Tipi

08-Kumanda Tipi 09-Faz Koruma 10-Kurtarma 11-Ptc 12-Krc

13-Pozisyon Reset 14-Revizyon Kesiciler 15-Dijital Ayarı

16-Display Çıkış 17-Maksimum İç Kayıt 18-Bodrum Sayısı 19-Yangın Durağı 20-Park Durağı 21-Park a Dönüş 22-Meşgul Süresi 23-Durak ta Bekleme

# Tek Hız Revizyonda Normalde

# Çift Hız Revizyonda Normalde

# Vvvf Hızlı Revizyonda Normalde

Yön+RF Yön+RF

Yön+RF (Hızlı)Yön+RH

Yön+RF (Hızlı)Yön+RH

(Yavaş) Yön+RF

(Yavaş) Yön

Sisteme enerji verildiğinde LCD ekranda “AÇILIŞ EKRANI” olarak adlandırdığımız ekran belirir. Bu ekranda kartın yazılım sürümü ve seri numarası gösterilmektedir. Ekran iki saniye bekledikten sonra, “ANA EKRAN”

olarak adlandıracağımız görüntüye geçecektir.

ESC butonuna 2 saniye basılı tutarak asansörü karttan revizyon konumuna alınız sonra yukarı ve aşağı butonları ile hareket ettiriniz.

7- HT-34 HIZ ÇIKIŞLARI

8- AÇILIŞ

9- KARTTAN REVİZYON

Yukarı veya Asağı butonlarına basıldığında manuel kayıt ekranı gelecektir.Du- rağı seçerek ENTER butonuna basınız.

10- TUŞLARDAN KAYIT VERMEK

11-PARAMETRE LİSTESİ

(10)

Türkçe 24-Kapı Açma Zamanı 25-Kilit Bekleme 26-Kapı Açık Hatası 27-Fotosel Bekleme 28-Hızlı Seyir Süresi

29-Yavaş Seyir Süresi 30-Rp Gecikmesi 31-Yön okları duruşta flash 32-Yön okları giderken flash 33-Bakım Süresi

34-Şifre Değiştirme 35-Sayıcı Tipi 36-Fabrika Ayar 37-Lisan / Language

00-KABİN SERİ KART

Bu parametre ile seri haberleşme kartının takılı olduğu ana karta bildirilir seri kart takılı ise bu parametre AKTİF yapılır

01-DURAK SAYISI

Asansörün durak sayısı bu parametre ile ayarlanır.

• 2-1

03-OTO KAPI KATTA - Açık bekleme - Kapalı Bekleme 05-TEK KAPI TAM OTO

Bu parametre ile çarpma kapılı asansörlerde tek kapısı otomatik olursa otomatik olan kat bu parametre ile belirlenir.

06-KAPI ÖZEL AYARI 02-KAPI TİPİ

Otomatik kapılar için aç-kapa sinyal tipini bu parametre yardımı ile ayarlayabilirsiniz.

• Çarpma Kapi: Sadece otomatik kapı olmayan asansörlerde kullanılır. •

• K.Oto Limitli: Sadece otomatik limitli kabin kapısı bulunan asansörlerde kullanılır.

• K.Oto Limitsiz: Otomatik limitsiz kabin kapısı bulunan asansörlerde kullanılır.

• Tam Oto Limitli: Tam otomatik limitli kapısı bulunan asansörlerde kullanılır.

• Tam Oto Limitsiz: Tam otomatik limitsiz kapısı bulunan asansörlerde kullanılır.

Bu parametre ile otomatik a ve b kapıların hangi katta açılacağı belirlenir Durak numarasını değiştirmek için durak rakamı yanıp sönerken YUKARI-ASAGI butonlarını kullanarak değiştirmek istediğiniz durağa geliniz. Daha sonra SAĞ butona basarak kapı değerinin üzerine geliniz.

Tekrar YUKARI-ASAGI butonlarını kullanarak açacak olan kapıyı belirleyiniz.,

• A-B- AB

(11)

Türkçe 07-ASANSÖR TİPİ

Asansörünüzün tahrik tipini bu parametre ile ayarlayabilirsiniz.

• Tek Hızlı Asansör : Tek-hız halatlı asansörler için bu ayar seçilmelidir.

• Çift Hızlı Asansör: Çift-hız halatlı asansörler için bu ayar seçilmelidir.

• Halatlı Vvvf: Kademesiz dişlili (asenkron makineli) ve dişlisiz (senkron makineli)

08-KUMANDA TİPİ

Asansörünüzün kumanda tipini bu parametre ile ayarlayabilirsiniz.

• Basit Kumanda: Kabin ve kat butonları paralel bağlanır. Sadece tek kayıt alır.

• Karışık Toplama: Kabin ve kat butonları paralel bağlanır. Kayıt hafızası tutulur.

• İnişte Toplama: Kabin ve kat butonları ayrı ayrı bağlanır. Kabin kayıtları iki yönde de toplanır. Kat çağrıları ise kabin aşağı doğru hareket ederken toplanır.

• Çift Yön Toplama: Kabin kayıtları ve katlardaki aşağı ve yukarı butonları ayrı ayrı bağlanır. Kabin kayıtları ve kat çağrıları hareket yönüne uygun şekilde toplanır.

09-FAZ KORUMA

Faz eksikliği ve faz sırası kontrolünü etkinleştirmek için bu parametreyi kullanabilirsiniz.

• İPTAL: Devre dışı.

• AKTİF: Faz sırasız • AKTİF: Faz sıralı 10-KURTARMA

Bu parametre ile kurtarma aktif seçilmesi sağlanır.Parametre aktif yapılır ise kurtarma aktif olur.

• AKTİF • PASİF 11-PTC

Bu parametre ile ptc motor termistörü girişi İPTAL veya AKTİF edilir • AKTİF Devre dışı.

• PASİF Devrede 12-KRC

Bu parametre kumanda kartının kontaktör geri besleme hatasına geçmesini iptal veya aktif eder. İptal edilirse kumanda kartı kontaktör yapışmalarını algılamaz.

• AKTİF KRC iptal olur • PASİF KRC aktif olur

(12)

Türkçe 13-POZİSYON RESET

Kumanda kartı şebeke elektriği kesilse bile son bulunduğu pozisyonu hafızasında tutacaktır. Fakat bazı özel durumlarda asansörün elektriği yeniden geldiğinde bir pozisyon sıfırlama istenebilir. Bu durumda asansör en alt kata 817 kesicisini görene kadar gidecektir. En alt kata varıldığında kat sayıcı sıfırlanır. Örneğin Akülü kurtarma ünitelerinin olduğu sistemlerde, bu parametre aktif yapılarak pozisyon sıfırlama sağlanabilir.

14-REVİZYON KESİCİLER

Revizyonda alt-üst limit kesicilerin hareket tarzını bu parametre ile ayarlaya- bilirsiniz.

• Kesiciye Kadar: Kesiciler kestiği anda katına gelmeden asansör durdurulur.

• Katina Kadar: Kesiciler kesse dahi asansör katına kadar gider.

15-DİJİTAL AYARI

Durak numarasını değiştirmek için durak rakamı yanıp sönerken YUKARI-ASAGI butonlarını kullanarak değiştirmek istediğiniz durağa geliniz. Daha sonra ENT butona basarak dijital değerin üzerine geliniz ve yazması gereken değeri giriniz. Eğer başka durak için de ayar yapacak isek ENT butona basıp tekrar değiştirmek istediğiniz durak üzerine geliniz ve aynı işlemi tekrarlayınız. İşlem sonunda ESC butonu ile menü den çıkınız.

Gösterge tipi Seçilebilecek çıkışlar

7-segment -4, -3, -2, -1, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, Gösterge 13, 14, 15, 16, , A, B, C,D, E, F, H, J, L, n, o, P

16-DISPLAY ÇIKIŞ

Bu parametre ile HT-34 kumanda kartı ve HT-SERİ kartın display çıkış ayarları yapılır.

• 7 Segment Çıkış: Devre dışı.

• Gray Kod Çıkış : Faz sırasız 17-MAKSİMUM İÇ KAYIT

Bu parametre kabin içerisinden verilebilecek olan maksimum kayıt sayısını belirler. Bu sayıya ulaşıldıktan sonra kabin içinden verilecek olan kayıt alınmaz.

• 01-10 durak arasında bir değer girilebilir.

18-BODRUM SAYISI

Asansörde bodrum kat var ise bu parametre ile ayarlanır

• 0-9

(13)

26-KAPI AÇIK HATASI

Kapı hata ya geçme süresi bu parametre ile ayarlanır.

• 2-250 Saniye

Türkçe

19-YANGIN DURAĞI

Yangın durağını parametre ile ayarlarız. Yangın (YAN) girişi aktif olduğunda asansör doğrudan tanımlanan kata gider ve kapıları açık olarak bekler.

Yangın sinyalinin kesilmesi ile asansör normal çalışmasına geri döner.

• İPTAL : Sistemde yangın durağı tanımlı değildir.

• 1-10 : Sistemde yangın 1-10’uncu durağa tanımlıdır.

20-PARK DURAĞI

Bu parametre ile asansörün ayarlanan süre sonunda hangi durağa gidip bekleyeceği ayarlanır.

21-PARKA GİDİŞ SÜRESİ

Park durağına gitmeden önce bekleme süresini bu parametre ile ayarlaya- bilirsiniz.

• 0-250 Saniye 22-MEŞGUL SÜRESİ

Meşgul süresi bu parametre ile ayarlanır.

• 2-20

24-OTO KAPI AÇ SÜRE

Bu parametre ile otomatik kapının açılıştan durmasına kadar olan süre girilir

• 05-20 Saniye

25-KİLİT BEKLEME SÜRESİ

Kapı kapalı sinyali geldikten sonra kilit (140) sinyalinin gelmesi için beklenecek maksimum süresi bu parametre ile ayarlanır.

• 8-30 Saniye

23-DURAKTA BEKLEME SÜRESİ

Toplama esnasında diğer kayıtlara gitmeden önce durakta bekleme süresini bu parametreden ayarlayabilirsiniz.

• 3-15 Saniye

EN81-1 ve EN81-2 standartlarına göre, manuel kapılı asansörlerde kabin kata geldikten sonra yeniden harekete geçmeden önce en az 2 saniye beklemelidir.

Basit kumandalı (toplamasız) asansörlerde bu parametre “KABIN LAMBA- SI” süresi ile aynı tutulmalı ve en az 2 saniye olarak ayarlanmalıdır.

(14)

Türkçe 27-FOTOSEL BEKLEME SÜRESİ

Bu parametre ile otomatik kapı açıldıktan sonra fotosel den gelen sinyal ile kapının kapanma süresini belirler.

28-HIZLI SEYİR SÜRESİ

Kabinin bir kattan diğer kata hareketi esnasında müsaade edilen maksimum seyir süresi bu parametre yardımı ile ayarlanır. Eğer bu süre aşılacak olursa, sistem otomatik olarak kabinin hareketini durdurur ve bloke olur.

• 5-120 Saniye

EN 81-1/2 standartlarına göre, motor çalışma zaman aşımı süresi aşağıdaki sürelerden küçük olanını aşmayacak şekilde uygun olarak sağlanmalıdır:

a. 45 saniye

b. En uzun seyir mesafesi + 10 saniye

c. En uzun seyir mesafesi 10 saniyeden az ise zaman aşımı süresi en az 20 saniye olmalıdır.

29-YAVAŞ SEYİR SÜRESİ

Asansörün hedef kata vardığında katta durdurucuyu görene kadar yavaş hızda hareket edeceği maksimum süre bu parametre yardımı ile ayarlanır.

Eğer bu süre aşılacak olursa kart otomatik olarak kabinin hareketini durdurur.

• 5-60 Saniye 30-RP GECİKMESİ

Halatlı VVVF sistemlerde ana kontaktör ün gecikmeli düşmesi istenebilir. Bu gibi durumlarda RP röle çıkışının gecikmesi bu parametreden ayarlanır.

Hidrolik asansörlerde ise motor gecikmesi olarak kullanılır 31-DURUŞTA FLASH

Bu parametre ile yön oku nun asansör katta dururken selektör yapması ayarlanır.

• 0000-2000 Milisaniye 32-GİDERKEN FLASH

Bu parametre ile yön oku nun giderken selektör yapması ayarlanır.

• 0000-2000 Milisaniye 33-BAKIM SÜRESİ

Kartınız çalıştığı sürece her gün bu parametrenin ayarlanan değeri 1 azalacaktır. Örneğin 45 güne ayarladığınız bu parametre 30 gün sonra 15 değerini gösterir ve 45 günün sonunda ise 0 değerini alır. Bu parametrenin 0 değerini alması durumunda asansörün hareket tarzı BAKIM SÜRE SONU parametresi ile ayarlanır. [gün].

• 0-250 gün

(15)

Türkçe 34-ŞİFRE DEĞİŞTİR

Bu parametre ile karta giriş şifresi değiştirilir veya belirlenir.

• 1_0_0_0_0 ise şifre aktif olur 35-SAYICI TİPİ

Bu parametre ile asansörün kat algılayıcı secimi yapılır • STANDART M0 : Standart M0 sayıcı • STANDART M1 : Standart M1 sayıcı 36-FABRİKA AYARI

Bu ekranda iken ENTER tuşuna basılarak TAMAM yazısı çıkıncaya kadar bekleyin. Sistem fabrika ayarlarına dönmüş olacaktır.

37-LISAN / LANGUAGE

Bu ekranda kartın lisanı ayarlanır.8 farklı lisan seçilebilir.

(16)

English

• One speed,Two speed,VVVF speed

• Dublex working

• Smart backligt

• 8 Launguage

• Pasword securıty

• Rescue mode

• Ding dong output

• 16 Stops

• With batery charge card (for serial card)

• Directional arrows Flash settings separate when stopping and going

• Car Serial or Paralel Comminication

• Phase Control

• 2 Door Control

• 7-segment, Gray code, Gray+1 code,Bınary code,Bınary+1 code, Floor lamp output

Lenght x Width x Hıght (mm) Protection Class

Operation Temperature Network Control İnputs Control Feed Voltage Power Usage Security Circuit Voltage Control Signal İnputs Control Signal Outputs

1-HT-34 GENERAL FEATURES

22-HT-34 TECNİCAL SPECIFICATIONS

3- BUTTONS FEATURES

285-85-20 IP20

±0- +60 °C 3 x 380V, 50Hz, N 24 ± 5 Vdc 400mA 10W, 24V için 230Vac

24 ± 5 Vdc 24 ± 5 Vdc

Menu can be set easily via the keypad recording error records are given the desired lift station can be observed.

ESC DWN UP ENT

(17)

• Introduction to Menu: Press the Enter key to enter the menu.

• Menu exit: Esc key and then press the Enter key on the menu çıkınız.

• Introduction Manuel motion: 3 seconds by pressing the Esc key to enter the action on the card revision

• Moving in the Menu: Up and down arrow keys to move within the menu.

HEYTECH HT-34 Control card, comply with EN81-1/2 standard, is an integrat- ed and electronic control card that has been designed for drive type hydraulic and roped Lifts. Users can make the programs of control card according to control and Lift system utilised by them by means of the keyboard on the LCD screen.

The system can make level renovation and early door opening with built-in door bridging relays.

There are built-in door relays for double automatic doors.

There is built-in phase control circuit.

For the Lift system to be electrically complies with EN81-1/2 standards:

• The electrical connections of the control card and control panel should be appropriate.

• Check certainly whether there is earth connection or not. Connect especially control panel, motor body, all safety device, cabin and its suspension to the earth line.

• Do not remove the glass housing without cutting the power of the control card.

• Dust, dirt, oil and rusting arising from the long-time working may prevent the good operation of the safety devices. During periodic maintenances, necessary cleaning should be performed.

• If your motor has mechanical brake switches, connect them.

This document has been prepared to inform the users. HEYTECH can make changes the content of the document, if required.

4-SAFETY NOTES

English

(18)

R, S, T MP 10A 120 130 140 A15 A3 A5 LIR LRO RP0 RP 1 2 S1A S1B 11 RU2 RU1 RH RF 100 1000 870 KRC

KAK CM SAK

Main Supply Mains Neutral Safety Circuit Neutral Stop Circuit

Door Plug Contact Circuit DoorLockCircuit

A Common signal of door open and door close A Door Close Signal

A Door Open Signal

Door PumpRelay Contact Openness Door Pump Relay Contact Joint Engine Contactor İnput RPA , RPB

Engine Contactor Output is Used İn VVVF and Hydraulıc (RPA,RPB) Cabine feed input

Cabine lıght output

Cabin Serial Communication Terminals (With Ht-34 SERIAL cards) Cabin Serial Communication Terminals (With Ht-34 SERIAL cards) RU1-RU2-RH-RF Partner

Up direction contactor Dwn direction contactor Fast speed relay output Low speed relay output Control circuit feed (+24v dc) Control circuit feed (-24v dc) Panel Revision Signal

Feedback Input of the main contactor. The normally closed contacts of the 100 signal of the main contactor must be connected serially to this entry KAK (Rescue ) contactor

SAK-KAK com

SAK (Panel voltage ) contactor

5-HT-34 Kumanda Kartı Üzerindeki Rumuzlar

English

(19)

K16 K19 K20 DTS PTC 817 818 M1 142 500 501 869 804 YAN DEP A,B,C, X01,X16 031 032 02 01 12

Door Open Limit Signal İnput Door Close Signal İnput Door open,photocell signal input Door Cloose button Signal input

Motor Thermistor & Panel Thermostat. As long as there is a signal Down Obligatory limit Magnetic Switch

Up Obligatory limit Magnetic Switch Floor counter magnetic switch input Floor stopper magnetic swıch ınput Revision Downward Button Revision Upward Button

Revision Key (from the Revision Box) Over load signal input

Fire Alarm Contact +24v dc Earthquake Alarm Contact +24v dc

7 Segment Digital output ( Gray ,Bınary output sett menu) Call İnput

Downward Arrow Light Upward Arrow Light Out of Service Light Output Owerload Light Output Busy Lights

6-HT-34 SERİAL CARD TERMİNAL İNPUT / OUTPUTS

SA SB 1000 100 2

Cabin Serial Communication Terminals (With Ht-34 SERIAL cards) Cabin Serial Communication Terminals (With Ht-34 SERIAL cards) Control circuit feed (-24v dc)

Control circuit feed (+24v dc) Cabine lıght output

English

(20)

1 K3 K5 K15 K16 K19 X01...X16 DD

A, B,C,D,E,F,G,2G 32

31 02 01 500 501 804 VAT K20 DTS HP, HP AB AA A+

A- -12 +12

Cabine feed input Door Close Signal Door Open Signal

Common signal of door open and door close Door Open Limit Signal İnput

Door Close Signal İnput Call İnput

Floor dıng dong sıgnal output

7 Segment Digital output ( Gray ,Bınary output sett menu) Upward Arrow Light

Downward Arrow Light Out of Service Lights Owerload Light Output Revision Downward Button Revision Upward Button Over load signal input Vatman Signal input

Door open,photocell signal input Door Cloose button Signal input Speaker

Alarm Signal ınput (+12V) Emergancy lamp output (+12V) Batery + İnput

Batery - İnput 12V - Output 12V + Output

English

(21)

00-Car Serial Card 01-Number of Stops 02-Door Type 03-Auto Door At Floor 04-Auto Door At Park 05-One Door Full Automatic 06-Special Door Setting

08-Command Type 09-Phase Control 10-Rescue Mode 11-Ptc 12-Krc-Contactor Control 13-Position Reset 14-Revision Braker

16-Display Output 17-Maksimum Car Call 18-Number of Basement 19-Fire Floor

20-Park Floor 21-Park Goıng Time 22-Busy Time 23-Waiting Time on

# One Speed Revision Normal

# Two Speed Revision Normal

# Vvvf Speed Revision Normal

Direction+RF Direction+RF

Direction+RF (Fast)Direction+RH

Direction+RF (Slow)Direction+RH

(Fast) Direction+RF

(Slow) Direction

When power is given the system, the “SPLASH SCREEN” will be appeared on the LCD screen. On this screen, the software version of the card and serial number are shown. After waiting for 2 seconds, the screen will select the display called as “MAIN SCREEN”.

Take the lift to the position of revision from card by pressing on ECS button for 2 seconds and then move it by up-down buttons.

7- HT-34 SPEED OUTPUTS

8- OPENINGSCREEN

9- REVISION FROM THE CARD

When press U-Down button, manual record monitor will appear. Select the station and then press ENTER button.

10- RECORD FROM BUTTONS

11-LİST OF PARAMETERS

English

(22)

24-Auto Door Opening Time 25-Waiting Lock Time 26-Door Open FaultTime 27-Waiting Photecell Time 28-Fast Cruising

29-Slow Cruising 30-Rp Delay 31-Flash in stance 32-Flash On The Go 33-Maintanence Time

34-Pasword Chanced 35-Counter Type 36-Factory Setting 37-Lisan / Language

00-CABIN SERIAL CARD

Set the communication speed between the main controller card and the serial communication card here. Or choose to ignore it.

01-NUMBER OF STOPS

Set the number of stops (maximum 16) here.

• 2-1

03-AUT.DOOR.AT.FLOOR

Set the open or closed position of the automatic door when waiting at floor.

- Waiting Open - Waiting Close

04-AUT.DOOR.AT.PARK

Set the open or closed position of the automatic door when waiting at park.

- Waiting Open - Waiting Close

05-ONE DOOR FULL AUT.

On elevators with swing doors, set this parameter when there’s only one full automatic door.

06-SPECIAL DOOR SETTING 02-DOOR TYPE

Set the open-close signal type for automatic doors here.

• Swing Door : Only for elevators that have no automatic door.

• Aut. Unlimited: Only used for elevators with automatic unlimited cabin doors.

• Aut. limited: Only used for elevators with automatic limited cabin doors

• Full Aut. Unlimited: Only used for elevators with full automatic unlimited cabin doors.

• Full Aut. limited: : Only used for elevators with full automatic limited cabin doors.

Set the floor at which you want to open the automatic A and B doors. When floor number is blinking, change the floor number with the UP-DOWN buttons till you come to the floor number you want to change. Press the ENTER button and next you will see the door setting blinking. Determine the door setting again by using the UP-DOWN buttons.

• A-B- AB

English

(23)

07-LIFT TYPE

You can set your lift drive type by this parameter.

-1 Speed Lift: For single-speed roped lifts, this setting should be selected.

-2 Speed Lift: For double-speed lifts, this setting should be selected.

-roped Vvvf: Asenkron machine

08-COMMAND TYPE

Set your elevator command type here.

• Simple Command: The cabin and floor buttons are connected parallely.

No other except the one registration is kept in memory.

• Mixed Collective : The cabin and floor buttons are connected parallely.

Registrations are kept in memory.

• Down Collective: The cabin and floor buttons are connected seperately.

Cabin registrations are collected from both sides. Floor calls are collected when when cabin moves in downward direction.

• Full Collective (both ways): Cabin registrations and the up and down buttons at the floors are connected seperately. Cabin registrations and floor calls are collected in appropriate manner of movement direction.

09-PHASE PROTECTION

Set the phase sequence or deactivate the phase here.

• Out of Order : Deactivate phase

• Phase unsequenced : Activates phase without sequence

10-RESCUE Rescue mode parameter • Active • Pasive 11-PTC

Choose the PTC motor thermistor input setting.

• ACTIVE:Activates it.

• CANCEL: Deactivates it.

12-KRC CONTACT FEEDBACK

Set here the bypassing of the contact feedback error. The controller card does not detect any contactor adhesion when it’s cancelled. If it is cancelled our company is not responsible.

• ACTIVE: Activating the contact feedback error • CANCEL: Bypassing the contact feedback error

English

(24)

13-POSITION RESET

Even when there’s a power blackout the controller card will remember its last position. But in some special cases when the power returns, a position reset may be wanted. In that case the elevator will go until it reaches the 817 limit switch of the bottom floor. When it reaches the bottom floor, the floor counter will reset. For example: with systems that have battery charged rescuers, this parameter can be activated to reset the position.

• ACTIVE:Activates it.

• CANCEL: Deactivates it.

14-REV. LIMIT SWITCH

Set the movement type of the up and down limit switches in revision.

• Until Limit switch: When limit switches are enabled the elevator will stop before reaching its floor.

• Until Floor: Even when limit switches are enabled the elevator will go to its floor.

15-DIGITAL SETTING

When the floor number is blinking, set the floor number with the UP-DOWN buttons till you come to the floor number you want to change. Press the ENTER button and next you will see the digits blinking. Set the value you like. When finished exit with the exit button. Or if you want to set another stop/floor, press the enter button, when floor number is blinking, repeat the steps.

7 Segment indicator

-4, -3, -2, -1, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 ,11, 12, 13, 14, 15, 16 A, B, C, D, E, F, H, J, L, N, O, P

16-DISPLAY OUTPUT

Set the display output of the HT-52 controller card and HT-52 SERI card.

• 7 Segment output Normal output.

• Gray code output Gray code output.

17-MAKSIMUM CAR CALL

Set the maximum amount of calls that can be registrated from within cabin.

When this number is reached it stops registrating any calls from within cabine.

01 - 15 Set the number of stops between the minimum and maximum.

18-NUMBER OF BASEMENT Set the number of basement here.

If the elevator is down collective, the floors that are under the basement that is set, it will be up collective.

Note: Used in command types except for down collective.

• 0-9

English

(25)

19-FIRE STOP

Set here the fire stop. When Fire input (at SIDE) is active the elevator goes to the defined floor directly and waits with its doors open. Elevator will return to normal operation mode when fire signal is over.

• 1-16 : Seconds This is the minimum and maximum time that is waited before going to park stop. Cancel Fire stop is not defined in the system.

20-PARK STOP

Set the park stop here. When elevator pauses its operation,it goes to this floor and waits with open doors.

21-RETURN TO PARK

Set the waiting time before going to park stop.

0 - 250 Seconds Set the waiting time between the minimum and maximum.

22-BUSY TIME

Set the cabin light delay here.

5 - 20 Seconds Set the cabin light delay time between the minimum and maximum

According to the EN 81-1/2 standarts it is not allowed to bypass the cabin light delay.

On elevators with simple command (non-collective) this parameter must me equal to the “WAIT AT STOP” time. And the busy time must be at least 2 seconds.

Set the waiting time before going to other registrations while collecting.

24-OPEN DOOR TIME

Set the time from opening till closing of the automatic door.

05 – 20 Seconds Set the door open-close time between the minimum and maximum.

25-LOCK WAITING

Set the maximum time to wait for the door lock signal (140) after getting the door closed signal.

8 - 30 Seconds Set the lock waiting time between the minimum and 23-WAITING TIME AT FLOOR

3 - 15 Seconds Set the waiting time at floor between the minimum and maximum

According to the EN81-1 and EN81-2 standarts, elevators with manual doors must have a waiting time of al least 2 seconds when moving again after reaching its floor.

On elevators with simple command (non-collective) this parameter must me equal to the “CABIN LIGHT” time and must be at least 2 second

English

(26)

English

27-PHOTOCELL WAITING TIME

Set the time of waiting for the photocell signal to close the door after the opening of the automatic door.

02 – 05 Seconds Set the photocell waiting time between the minimum and maximum.

28-FAST CRUISING TIME

Set the maximum time of cruising between 2 stops. If this time should be exceeded, the system automatically stops the movement of the cabin and blocks it.

0 - 100 Seconds Set the fast cruising time between the minimum and maximum.

According to the EN81-1 / 2 standards motor operation time work must not exceed the smaller of the following:

• 45 seconds

• Longest cruising distance +10 seconds

• If longest cruising distance is less than 10 seconds, the timeout should be at least 20 seconds.

29-SLOW CRUISING TIME

Set the maximum time of slow cruising from the moment it meets the stopper of the target floor. If this time should be exceeded, the system automatically stops the movement of the cabin and blocks it.

0 - 100 Saniye Set the slow cruising time between the minimum and maximum.

30-RP DELAY

It could be demanded with roped VVVF systems to delay the fall of the main contactor. In such cases, the RP delay of the relay output is set by this parameter.

00000 – 25000 Miliseconds Set the contactor delay time between the minimum and maximum.

31-FLASH IN STANCE

Direction arrow is set to flash. (At stop)

• 0000-2000 Milisecond 32-FLASH ON THE GO

Direction arrow is set to flash. (while moving)

• 0000-2000 Milisecond

26-DOOR STILL OPEN ERROR

If after the time set in this parameter the door is not closed yet the control panel will go out of service. It is possible to choose to bypass this function.

0 - 250 Seconds Set the time for passing the door still open error between the minimum and maximum.

(27)

33-MAINTENANCE TIME

For every day the card operates the value of this parameter drops by one.

For example, if it is set for 45 days, this parameter will show a value of 15 when 30 days have passed. After 45 days the value will be 0.

45 - 250 Days Set the maintenance time between the minimum and maximum.

English

34-CHANGE PASSWORD Set or change the password code here.

• 1_0_0_0_0 If the display looks like this, the password is in activated.

MANUFACTURER INFORMATION

HEYTECH ELEKTRİK ELEKTRONİK SANAYİ VE TİCARET A.Ş 35-COUNTER TYPE

Set here your selection of the elevator floor sensor.

Standard M0: Standard M0 counter.

Standard M1: Standard M1 counter.

36-FACTORY SETTINGS

Here you can cancel your settings and return to factory settings.

37-LISAN / LANGUAGE

In this screen, the language of the card is set. 8 different languages can be selected.

(28)

• Управление одно-, двухскоростными приводами, а также приводами с частотным регулированием

• Работа в группе (две станции)

• 16 остановок

• Последовательный и параллельный протоколы обмена

• Контроль за порядком фаз 380В

• Поддержка управления 2-я дверями кабины

• 8 языков в меню

• Режим спасения

• Выход сигнала "динг-донг"

• Заряд 12В батареи (в плате ревизии)

• Защита паролем настроек платы

• Индивидуальная настройка индикации направления движения при движении кабины, а также на остановке

• Выходной сигнал в формате 7-сегментного, грей кода, грей кода +1, бинарного, бинарного +1 коды

• Умное управление подсветкой

• Управление освещением

Длина х Ширина х Высота (мм) Класс защиты

Рабочая температура

Напряжение питания контролируемое Напряжение питания платы Потребление и мощность Цепи безопасности Входные сигналы управления Выходные сигналы управления

1-Общие возможности HT-34

2-Техническая спецификация HT-34

3-Кнопки управления

285-85-20 IP20

±0- +60 °C 3 x 380V, 50Hz

24 ± 5 В постоянного тока 400 мА, 10 Вт, 24 В постоянного тока 230 В переменного тока

24 ± 5 В постоянного тока 24 ± 5 В постоянного тока

ESC DWN UP ENT

Меню платы и настройки изменяются с помощью кнопок управления. Состояние и ошибки работы отображаются на экране платы управления.

Русский

(29)

• Меню: Нажмите "Enter" для входа в меню платы. Используйте эту клавишу для выбора параметра и подтверждения изменения значения пункта меню.

• Выход из меню: Нажмите клавишу "ESC" и затем "Enter" для подтверждения выхода из меню. Используйте эту кнопку для отмены изменения значения пункта меню.

• Ручное управление: Нажмите "ESC" на более чем 3 секунды для перехода из нормального режима управления в режим ревизии и ручного управления. Нажимайте "UP" и "DOWN" для движения кабины.

Нажмите "ESC" для возврата в нормальный режим работы.

• Движение по меню: Нажимайте "UP" и "DOWN" кнопки для перемещения по меню.

Плата HEYTECH HT-34 соответствует нормам EN81-1/-2.

Плата HT-34 является интегрированной платов, которая была разработана для управления электрическими лифтами. Используя кнопки меню, Вы можете менять значения управляющих величин для достижения необходимого типа управления с одновременным взаимодействием с контрольными сигналами. Плата обеспечивает выравнивание, а также движение с открытыми дверями.

В наявности управление двумя дверями лифта, а также контроль за порядком фаз входного напряжения 380В.

Для обеспечения соответствия нормам EN81-1/-2:

• Обеспечение соответствующих подсоединений платы и панели управления.

• Проверить наличие заземления и есть или нет заземление.

Соедините все узлы как панель управления, привод, узлы безопасности, кабину к заземлению.

• Не удаляйте защитное стекло с платы управления, не отключив от питания.

• Пыль, грязь, масло и другие загрязнения от долговременной работы могут влиять на работу и обеспечение безопасности устройств. Обратите внимание на необходимость периодической очистки при плановым обслуживании.

• Если Ваша лебедка имеет выключатель срабатывания механического тормоза, рекомендуется подключить сигнал выключателя к плате.

Этот документ подготовлен для извещения пользователей про принципы работы.

Компания HEYTECH может вносить изменения в документ без уведомления.

4 - Указания по безопасности

Русский

(30)

R, S, T MP 10A 120 130 140 A15 A3 A5 LIR LRO RP0 RP 1 2 SA SB 11 RU2 RU1 RH RF 100 1000 870 KRC

KAK CM SAK

Сигналы питания 380В Общая нейтраль (380В) Нейтраль цепи безопасности Цепь ОСТАНОВКИ

Цепь контроля закрытия ДВЕРЕЙ ШАХТЫ Цепь контроля закрытия ДВЕРЕЙ КАБИНЫ

Общий сигнал для управления закрытия и открытия двери Сигнал ОТКРЫТИЯ двери

Сигнал ЗАКРЫТИЯ двери

Сигнал управления дверным магнитом (для ручных дверей) Общий вход управления дверным магнитом

Вход контакторов мотора RPA , RPB

Выход контактор RPA,RPB (VVVF и гидравлический привод) Вход управления освещения кабины

Выход освещения кабины

Контакт серийного интерфейса обмена с кабиной (Необходима плата Ht-34 SERIAL)

Контакт серийного интерфейса обмена с кабиной (Необходима плата Ht-34 SERIAL)

Общий вход для RU1-RU2-RH-RF Выход контактора ВВЕРХ Выход контактора ВНИЗ

Выход контактора БОЛЬШАЯ СКОРОСТЬ Выход контактора МАЛАЯ СКОРОСТЬ Питание платы (+24 В)

Питание платы (-24 В) Сигнал ревизии платы

Сигнал обратной связи срабатывания главного контактора.

Сигнал питания 100 через нормально закрытые контакты подключается к этому входу

спасательный контактор SAK-KAK общий сигнал.

сетевой контактор

5 - HT-34 Входы и выходы платы управления

Русский

(31)

K16 K19 K20 DTS PTC 817 818 M1 142 500 501 869 804 YAN DEP A,B,C, X01,X16 031 032 02 01 12

Вход сигнала ограничителя ОТКРЫТИЯ двери Вход сигнала ограничителя ЗАКРЫТИЯ двери Входной сигнал от кнопки ОТКРЫТИЯ двери. Также используется для включения сигнала фотозавесы Входной сигнал от кнопки ЗАКРЫТИЯ двери.

Вход термистора привода и панели. 24Vdc Вход ограничителя движения ВНИЗ от датчика Вход ограничителя движения ВВЕРХ от датчика Вход этажного счетчика

Вход точной остановки на этаже

Сигнал движения в ревизии от кнопки ВНИЗ Сигнал движения в ревизии от кнопки ВВЕРХ Сигнал включения режима ревизии (от блока ревизии) Сигнал ПЕРЕГРУЗКИ

Сигнал ПОЖАРНОЙ СИГНАЛИЗАЦИИ (+24 В) Сигнал ЗЕМЛЕТРЯСЕНИЯ (+24 В)

7 Segment цифровой выход (Грей код и бинарный согласно настройки меню)

Сигналы вызовов

Выход включения индикатора ВНИЗ Выход включения индикатора ВВЕРХ Выход сигнала НЕ ОБСЛУOЖИВАЕТСЯ Выход сигнала ПЕРЕГРУЗКА Выход сигнала ЗАНЯТ

6-Входы и выходы платы ревизии HT-34 SERIAL CARD

SA SB 1000 100 1

Контакт серийного интерфейса обмена с платой управления Питание платы (+24 В)

Питание платы (-24 В)

Вход управления освещения кабины Выход освещения кабины

Русский

(32)

2 K3 K5 K15 K16 K19 X01...X16 DD

A, B,C,D,E,F,G,2G 32

31 02 01 500 501 804 VAT K20 DTS HP, HP AB AA A+

A- -12 +12

Выход освещения кабины Сигнал ОТКРЫТИЯ двери Сигнал ЗАКРЫТИЯ двери

Общий сигнал для управления закрытия и открытия двери

Вход сигнала ограничителя ОТКРЫТИЯ двери Вход сигнала ограничителя ЗАКРЫТИЯ двери Сигналы вызовов

Выход сигнала "Динг-Донг" на этаже

7 Segment цифровой выход (Грей код и бинарный согласно настройки меню)

Выход включения индикатора ВНИЗ Выход включения индикатора ВВЕРХ Выход сигнала НЕ ОБСЛУOЖИВАЕТСЯ Выход сигнала ПЕРЕГРУЗКА

Сигнал движения в ревизии от кнопки ВНИЗ Сигнал движения в ревизии от кнопки ВВЕРХ Сигнал ПЕРЕГРУЗКИ

Сигнал движения только по вызовам из кабины (Vatman)

Входной сигнал от кнопки ОТКРЫТИЯ двери. Также используется для включения сигнала фотозавесы Входной сигнал от кнопки ЗАКРЫТИЯ двери.

Динамик

Вход сигнала ТРЕВОГИ

Выход питания лампы аварийного освещения (+12V) Выход питания батареи +12В

Выход питания батареи -12 В Выход -12 В

Выход +12 В

Русский

(33)

00-Серийная плата 01-Количество остановок 02-Тип дверей

03-Ожидание двери на этаже 04-Двери на парковочном этаже 05-Одни двери полностью автоматические 06-Спецификация двери

08-Тип команд 09-Защита фаз 10-Эвакуация 11-Терморезистр 12-Контроль к онтактора 13-Сброс позиции 14-Ограничение

15-Установка индикации 16-Вывод дисплея 17-Максимальные вызовы кабины

18-Номер подвала 19-Пожарная остановка 20-Парковочная остановка 21-Ожидание перед Одна скорость

Ревизия Работа

Две скорости Ревизия

Работа (медленно) Работа (быстро)

Частотное управление Ревизия

Работа (медленно) Работа (быстро)

(RU2/RU1)+RF (RU2/RU1)+RF

(RU2/RU1)+RF (RU2/RU1)+RF (RU2/RU1)+RH

(RU2/RU1)+RF (RU2/RU1)+RF (RU2/RU1)+RH

При включении питания, на экране отображается "ЭКРАН ПРИВЕТСТВИЯ" на ЖК индикаторе. На этом экране отображается версия платы и серийный номер. После 2-х секунд, экран переключатеся в "ГЛАВНОЕ МЕНЮ".

TНажмите кнопку "ESC" на плате более чем на 2 секунды. Затем нажимайте кнопки "ВВЕРХ" И "ВНИЗ" для движения кабины.

Нажмите кнопку "ESC" еще раз для завершения работы и перехода в нормальную роботу.

7 - Сигналы управления скоростями HT-34

8 - Экран приветствия

9 - Ревизия с платы

Для того, чтобы отправить кабину лифта на необходимый этаж, нажмите кнокпи "ВВЕРХ" или "ВНИЗ". Появится экран ручной регистрации вызовов. Выберите этаж и нажмите "ENTER".

10- Вызовы с кнопок платы

11-Список параметров

Русский

(34)

Русский

22-Время ожидания 23-Время ожидания на этаже 24-Время открытия автоматических дверей 25-Время закрытия замка 26-время ошибки открытых дверей

27-Ожидание фотозавесы 28-Время движения на большой скорости

29-Время движения на малой скорости 30-Время переключения RP 31-Мигание на этаже

32-Мигание при движении 33-Период обслуживания 34-Установить пароль 35-Тип счетчика 36-Заводские настройки 37-Язык

00-Серийная плата

Установка скорости обмена между контроллером и платой серийного интерфейса. Выберите скорость или игнорировать.

01- Количество остановок

Установка количества остановок (максимум 16)

• 2-16

03-Ожидание двери на этаже

Установите режим ожидания на этаже – с открытыми или закрытыми автоматическими дверями.

- Ожидание с открытыми дверями - Ожидание с закрытыми дверями 04-Двери на парковочном этаже

Установите режим ожидания на парковочном этаже – с открытыми или закрытыми автоматическими дверями - Ожидание с открытыми дверями

- Ожидание с закрытыми дверями

05-Одни двери полностью автоматические

On elevators with swing doors, set this parameter when there’s only one full automatic door.

02-Тип дверей

Установка типа сигнала открытия-закрытия для автоматических дверей

•Impact Door : Только для лифтов без автоматических дверей.

• Aut. Unlimited : Только для лифтов с автоматическими дверями кабины без ограничителей.

• Aut. limited : Только для лифтов с автоматическими дверями кабины с ограничителями.

•Full Aut. Unlimited : Только для лифтов с полностью автоматическими дверями кабины без ограничителей.

Full Aut. limited : Только для лифтов с полностью автоматическими дверями кабины с ограничителями.

В соответствии с требованиями EN 81-1/2 в случае аварийной остановки, ревизии и возврат назад, автоматические двери должны быть закрытыми.

(35)

07-Тип лифта Выберите тип лифта.

1 SPEED LIFT: Односкоростной лифт.

2 SPEED LIFT: Двухскоростной лифт.

ROPED VVVF: Лифт с частотным приводом 08-Тип команд

Выберите тип команд управления лифтом.

Simple Command : Кабина и этажные кнопки подключены параллельно. Регистрируется только один вызов

Mixed Collective : Кабина и этажные кнопки подключены параллельно. Регистрация вызовов фиксируется в памяти Down Collective : Кабина и этажные кнопки подключены отдельно. Регистрация вызовов кабины идет в два направления.

Этажные вызовы выбираются, когда кабина движется ВНИЗ.

Full Collective (both ways) : Кабина и этажные кнопки подключены отдельно. Регистрация вызовов кабины и этажные вызовы фиксируются все

09-Защита фаз

Выберите тип контроля за порядком фаз или отключите.

• Out of Order : Не контролируется порядок

• Phase unsequenced : Порядок фаз без порядка

• Phase sequenced: Фазы должны быть в порядке. Обычно используется для одно- и двухскоростных лифтов

10-Эвакуация Rescue Mode Активно (эвакуация) Пасивно (двери В)

11- Терморезистр

Выберите контроль за терморезистором лебедки.

Активно Не активно

Русский

06-Спецификация двери

Установите этаж на котором Вы хотите использовать двери А или В. Когда номер этажа мигает, измените номер этажа (используя клавиши ВВЕРХ/ВНИЗ), пока не выберете необходимый этаж. Нажмите "ENTER" и затем Вы увидите, что мигают настройки дверей. Выберите тип дверей используя клавиши ВВЕРХ/ВНИЗ.

• A-B- AB – двери А, двери В, одновременно А и В

(36)

13-Сброс позиции

При выключении платы управления, плата запоминает свою последнюю позицию. Но в некоторых случаях, при возобновлении питания, требуется сброс позиции. В этом случае, лифт идет на позицию 817, по достижению которого счетчик этажей сбрасывается на начальную позицию. Например, для систем с системами эвакуации на батареях, этот параметр может быть активен.

Активировать сброс Не выполнять сброс позиции

15-Установка индикации

Когда номер остановки мигает, выберите номер остановки используя кнопки ВВЕРХ/ВНИЗ, пока не выберете необходимый Вам номер остановки. Нажмите "ENTER" и Вы увидите мигающий тип цифры индикатора. Выберете необходимое Вам значение.Нажмите "ENTER" для записи значения, "ESC" для выхода. Если необходим другая остановка, продолжайте выбирать номер остановки используя ВВЕРХ/ВНИЗ.

7 сегментный идикатор. Доступные значения

-4, -3, -2, -1, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 ,11, 12, 13, 14, 15, 16 A, B, C, D, E, F, H, J, L, N, O, P

16-Вывод дисплея

Тип вывода информации на контроллере HT-34 Нормальный выход.

Выход в Грей коде.

Русский

12-KRC Контроль контактора

Установите тут контроль за срабатыванием контакторов привода. Если установлено "ОТМЕНА", тогда контроль не осуществляется. В этом случае наша компания не несет ответственности.

Активировать контроль контактора Выключить контроль контактора

14-Ограничение движения в ревизии

Установите тип движения по достижению в ревизии позиции верхнего/нижнего ограничителя.

Until Limit switch: Когда ограничители активны, лифт останавливает кабину до достижения остановки.

Until Floor: При достижении ограничителя, кабина лифта будет двигаться до достижения остановки.

(37)

17-Максимальные вызовы кабины

Установите максимальное значение вызовов, которые будут регистрироваться с кабины. Когда достигается максимальное значение вызовов, все остальные вызовы игнорируются.

01 - 15 Установите количество остановок.

18-Номер подвала

Установите номер остановки, которая будет разделяющая между остановками. Если тип управления выбран "Сбор вниз", то вызовы ниже этой остановки будут собирательные вверх.

Внимание: Только для типа управления "Сбор вниз".

19-Пожарная остановка

Установите номер пожарной остановки. Когда будет активен сигнал ПОЖАР, лифт движеться только к этому этажу и ждет с открытыми дверями. При снятии сигнала, лифт возвращается в нормальный режим.

• 1-16 : Остановка.

Выберите "Cancel" для отмены режима, когда пожарная остановка не определена в системе.

20-Парковочная остановка

Установите номер парковочного этажа тут. Когда лифт не вызывается, он движеться на этот этаж.

01 - 16 Остановка.

21-Парковочная остановка

Установите время возврата на парковочную остановку.

0-250 секунд.

22-Время ожидания

Установите время освещения в кабине.

5 - 20 секунд.

В соответствии с требованиями стандарта EN 81-1/2 не разрешено убирать задержку освещения кабины.

В лифтах с типом сбора "ПРОСТОЕ", этот параметр должен быть не менее 2 секунд.

Установите время задержки перед переходом к регистрации других вызовов при сборе.

23-Время ожидания на этаже Установите время ожидания на этаже 3 - 15 секунд

В соответствии с требованиями стандарта EN 81-1/2, лифт с ручными дверями должен иметь не менее 2 секунд перед движением снова после достижения остановки.

На лифте с типом сбора "ПРОСТОЕ", этот параметр должен

Русский

(38)

Русский

27-Ожидание фотозавесы

Установите время задержки сигнала закрытия двери после появления сигнала от фотозавесы.

02 – 05 секунд

28-Время движения на большой скорости

Установите время движения между двумя соседними остановками на большой скорости. Если это время будет исчерпано, система автоматически остановит и блокирует движение кабины.

0 - 100 секунд

Согласно требований стандарта EN81-1 / 2 время работы привода не должен быть меньше наименьшей из величин:

• 45 секунд

• Наибольшое расстояние +10 секунд

• Если наименьшая дистанция в движении менее 10 секунд, время должно быть не менее 20 секунд.

29-Время движения на малой скорости

Установите время движения при переходе с большой скорости до достижения датчика остановки. Если это время будет исчерпано, система автоматически остановит и блокирует движение кабины.

0 - 100 секунд.

26-время ошибки открытых дверей

IУстановите время закрытия двери на остановке. После истечения этого времени, плата управления переходит в режим НЕ ОБСЛУЖИВАЕТСЯ. Возможно установить пропуск этого параметра.

0 - 250 секунд

24-Время открытия автоматических дверей

Установите время от открытия до закрытия автоматических дверей.

05 – 20 секунд

25-Время закрытия замка

Установите время ожидания сигнала закрытия дверей (140) после сигнала закрытия дверей.

8 - 30 секунд.

Referanslar

Benzer Belgeler

Yine oda sıcaklığında 2.59x10 6 s doğal yaşlandırılan numunelerin DTA ve DTK verilerindeki (c) eğrileri, bu süre içerisinde yapıda oluşan GPB(Cu,Mg)

Numunelerin daha önceden belirlenen (Hasırcı,2000), sertlik, darbe ve çekme dayanımı özellikleri, işlenebilirlik değerlerinde elde edilen (Aşkun,2001) asıl kesme kuvveti

soğutulan örneğinde martensite faz dönüşümü gözlendi.. Cu-%13,81Mn-%3,78Al alaşımında yavaş soğutulan örnekte çökelti, hızlı soğutulan örnekte ise

BOR TOKSĠKLĠĞĠ; bor kapsamı yüksek sularla sulama yapılan bölgelerde ve bitkilerde, denizsel kökenli ana materyal üzerinde oluĢmuĢ kurak ve yarı-kurak bölge

Galdós ninguna de las tentaciones que al hombre de letras asedian en nuestra patria (ni siquiera la tentación política, la más funesta y enervadora de todas), se ha mostrado

Pylori related duodenal ulcer, there are lower levels of Cu/Zn- superoxide dismutase (SOD) and prostaglandin E2 (PGE2) in gastric mucosa during severe duodenal ulcer and

Bunu bir örnekle açıklayalım: Kaçırılan, araba kazası geçiren ya· da cinsel saldırıya uğrayan bir çocuk, çeşitli korkular ve bunalımlar geliştirir.

TEK'in daha verinıIi çalışması içinTürkiye Elektrik Dağtm ve Türkive Elektrik ü;timlüedm -. anonim şirteıleri olmak izere ikiye aynlöğıü