• Sonuç bulunamadı

Uncomplicated retainment of metal coronary bulldog clips recognized five years after coronary artery bypass graft surgery

N/A
N/A
Protected

Academic year: 2021

Share "Uncomplicated retainment of metal coronary bulldog clips recognized five years after coronary artery bypass graft surgery"

Copied!
2
0
0

Yükleniyor.... (view fulltext now)

Tam metin

(1)

432 Turkish J Thorac Cardiovasc Surg 2011;19(3):432-433 Türk Göğüs Kalp Damar Cerrahisi Dergisi

Turkish Journal of Thoracic and Cardiovascular Surgery

doi: 10.5606/tgkdc.dergisi.2011.057

Uncomplicated retainment of metal coronary bulldog clips recognized

five years after coronary artery bypass graft surgery

Koroner arter bypass greftleme ameliyatından beş yıl sonra farkedilen unutulmuş

komplikasyonsuz metal koroner buldog klempi

Murat Tulmaç,1 Nurtaç Özer,1 Haksun Ebinç,1 Vedat Şimşek,2 M. Tolga Doğru1

1Department of Cardiology, Medicine Faculty of Kırıkkale University, Kırıkkale; 2Department of Cardiology, Sivas Numune Hospital, Sivas

Koroner arter bypass cerrahisi sırasında mediyastinde metal koroner bulldog klempi unutulan ve beş yıllık komplikas-yonsuz bir sürenin ardından kararsız anjina pektoris tanısıy-la yapıtanısıy-lan koroner anjiyografisinde tesadüfen yabancı cisim tespit edilen bir hasta sunuldu. Bu olgu ameliyat sonrası dönemde yabancı cisim unutulduğu fark edilen hastalarda konservatif tedavinin tekrar ameliyata bir alternatif olarak akılda tutulması gerektiğini düşündürmektedir.

Anah tar söz cük ler: Buldog klempi; koroner anjiyografi; koroner arter bypass ameliyatı; unutulmuş cerrahi gereçler.

We report a patient with retained metal coronary bulldog clips in the mediastinum during coronary artery bypass surgery which was recognized during coronary angiography following the diagnosis of unstable angina pectoris after an uncomplicated period of five years. This case suggests that conservative management of patients with postoperatively recognized retained foreign material should be kept in mind as an alternative to reoperation.

Key words: Bulldog clips; coronary angiography; coronary artery bypass graft surgery; retained surgical material.

Received: November 10, 2008 Accepted: February 23, 2009

Correspondence: Murat Tulmaç, M.D. Kırıkkale Üniversitesi Tıp Fakültesi, Kardiyoloji Anabilim Dalı, 71100 Kırıkkale, Turkey. Tel: +90 318 - 225 24 85 e-mail: mtulmac@yahoo.com

We report a patient with retained metal coronary bulldog clips found in the mediastinum during coronary artery bypass graft surgery which were recognized after an uncomplicated period of five years.

CASE REPORT

A 78-year-old man was admitted to our hospital with exertional chest pain which had begun two months before. He had received coronary artery bypass graft surgery five years ago with saphenous vein grafts to the left anterior descending artery and right coronary artery. His physical examination was normal. In a chest X-ray, a radiopaque, dense, metal material was observed (Figure 1). In lateral chest X-ray, the material was shown in the posterior mediastinum (Figure 2). Apical hypokinesia was revealed in transthoracic echocardiography. Erythrocyte sedimentation rate and C reactive protein levels were normal.

His coronary angiography demonstrated patent saphenous vein grafts (Figure 3, 4) and a new lesion

in the circumflex coronary artery with 95% diameter stenosis (Figure 5). Metal coronary bulldog clips were observed in the posterior mediastinum without any association with vessels. The circumflex coronary artery lesion was treated with provisional stenting without complication. The patient was informed about the patency of the saphenous vein grafts and the harmless foreign material. In the six-month control, the patient was healthy and free from angina.

DISCUSSION

Surgical material inadvertently left inside the patient is an important complication in surgical procedures. Retained foreign items not only can cause serious or even fatal injuries, but also lead to increased costs and bad reputations for clinicians and treating institutions. The rate of retained foreign material is 1/7000 in coronary bypass surgeries.[1] This is the first case reporting

(2)

Tulmaç ve ark. KABG ameliyatından beş yıl sonra farkedilen unutulmuş komplikasyonsuz metal koroner buldog klempi

Türk Göğüs Kalp Damar Cer Derg 2011;19(3):432-433 433

In this case, metal bulldog clips retained in the mediastinum did not result in any complication. Metal surgical materials incidentally found to be retained soon after surgery may be followed up without reoperation if they do not result in hemodynamic compromise, foreign body reaction, or risk of infection.

Declaration of conflicting interests

The authors declared no conflicts of interest with respect to the authorship and/or publication of this article.

Funding

The authors received no financial support for the research and/or authorship of this article.

REFERENCES

1. Egorova NN, Moskowitz A, Gelijns A, Weinberg A, Curty J, Rabin-Fastman B, et al. Managing the prevention of retained surgical instruments: what is the value of counting? Ann Surg 2008;247:13-8.

Figure 1. In posterior anterior chest X-ray a radiopaque metal dense material was observed.

Figure 2. In lateral chest X-ray the material was shown in posterior mediastinum.

Figure 3. Saphenous vein grafts to anterior descending artery is patent and not associated with bulldog clips.

Figure 4. Saphenous vein grafts to right coronary artery are also

Referanslar

Benzer Belgeler

Frequency of early occlusion and stenosis in a left internal mammary artery to left anterior descending artery bypass graft after surgery through a median sternotomy on

In this study, we aimed to investigate the prevalence of postoperative delirium in patients undergoing coronary artery bypass grafting and to identify possible risk

The indications for the utilization of the device were the presence of proximal aortic calcifications and atherosclerotic plaques in coronary artery bypass graft

Our case was characterized with difficulties in assisted mechanical ventilation after coronary artery bypass grafting due to excessive lung tissue compressing

Superficial and deep sternal wound infection after more than 9000 coronary artery bypass graft (CABG): incidence, risk factors and mortality.. Disruption and infection

In this article, we report an 81-year-old male case with a complication of percutaneous coronary intervention where the balloon catheter was entrapped in the right

Free bowel perforation after off-pump coronary artery bypass graft surgery: a rare complication of Crohn’s disease.. Atan kalpte koroner arter baypas greft cerrahisi sonrasında

Preoperative white blood cell count is independently associated with higher perioperative cardiac enzyme release and increased 1-year mortality after coronary artery