• Sonuç bulunamadı

Deployment of a SUPERA stent in a dis- sected lesion in the axillary artery

N/A
N/A
Protected

Academic year: 2021

Share "Deployment of a SUPERA stent in a dis- sected lesion in the axillary artery"

Copied!
1
0
0

Yükleniyor.... (view fulltext now)

Tam metin

(1)

E-page Original Images

Deployment of a SUPERA stent in a

dis-sected lesion in the axillary artery

A 71-year-old male patient with a history of lower extremity peripheral artery disease had presented to another hospital with an intermittent arm claudication. A dissected lesion extending

a

b

c

Figure 1. (a) The dissected segment extending from subclavian artery to axillar artery. (b, c) A SUPERA stent was successfully deployed in the dissected segment

from subclavian artery into axillary artery was demonstrated dur-ing peripheral angiography. The lesion did not limit the blood flow, thus the patient was prescribed aerobic exercise program. Three months later the patient presented to our hospital and stated that the severity of the pain did not reduce despite adherence to the prescribed exercise program. An endovascular intervention to the dissected lesion in the subclavian artery was decided after analyzing the prior peripheral angiography. A SUPERA stent was chosen to be deployed in the dissected segment to prevent high-er risk of stent restenosis and fracture. Right brachial arthigh-ery was preferred as access site because of the history of lower extrem-ity peripheral artery disease. Brachial artery was cannulated us-ing the 6 French (F) sheath. The dissected lesion in the axillary artery extending into the subclavian artery was observed during the diagnostic peripheral angiography (Fig. 1a). The catheter pre-mounted with SUPERA stent was advanced over the wire until it was ensured that the stent completely covered the target lesion. A 6.0×80 mm SUPERA stent was successfully deployed in the le-sion (Fig. 1b, 1c). Post-dilation with a 6.0×80 mm was performed. Final result was optimal (Fig. 2; Video 1) and the patient was dis-charged; he was prescribed dual antiplatelet regimen consisting of acetylsalicylic acid and clopidogrel for 6 months.

Video 1. Optimal implantation of a SUPERA stent on the axil-lary artery.

Göksel Çinier, Can Yücel Karabay, Barış Güngör, Ömer Kozan Department of Cardiology, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training and Research Hospital; İstanbul-Turkey

Address for Correspondence: Dr. Göksel Çinier, Dr. Siyami Ersek Göğüs Kalp ve Damar Cerrahisi Eğitim ve Araştırma Hastanesi, Tıbbiye Cad. 34107 Kadıköy-İstanbul-Türkiye

Phone: +90 532 484 23 50 E-mail: cinierg@gmail.com

©Copyright 2018 by Turkish Society of Cardiology - Available online at www.anatoljcardiol.com

DOI:10.14744/AnatolJCardiol.2018.27475

E-10

Figure 2. An optimal result was achieved following the deployment of a SUPERA stent

Referanslar

Benzer Belgeler

implantation via the left axillary artery route in a patient with a permanent pacemaker: The first transaxillary artery route.. experience with a Meril’s

A relatively forceful injection, ex- ceeding the capacity of the isolated septal artery (assumed to take a right anterior oblique image of the RCA), resulted in mul-

To the best of our knowledge, intramyocardial rupture of an isolated septal coronary artery was first defined in a patient with myocar- dial noncompaction and concurrent

On coronary angiography, 60% proximal stenosis in first diagonal branch of left anterior descending artery, 70% stenosis after first diagonal branch and 100% stenosis after

The severity of ST segment elevation in acute inferior myocardial infarction: Does it predict the presence of a proximal culprit lesion along the right coronary artery courseO.

[4] However, in the presence of severe respiratory symptoms, severe tracheal stenosis, a history of frequent hospitalization, or sudden respiratory arrest due to reflex apnea or

Computed tomography (CT) angiography showed a ruptured saccular axillary artery aneurysm (35x40 mm) and subclavian artery (13 mm in diameter) dilatation (Figure 1).. The

Alternative arterial cannulation sites to the ascending aorta in cardiopulmonary bypass (CPB) are the transverse arch of the aorta, descending aorta, femoral artery,