Cardiac output measurement during cardiac surgery:

esophageal Doppler versus pulmonary artery catheter

蔡佩珊

Su NY;Huang CJ;Tsai P;Hsu YW;& Cheng CR 摘要

Abstract

BACKGROUND: Bolus thermodilution cardiac output (BCO) measurement has been considered as the "gold standard" for cardiac output (CO) measurement. However, it requires placement of a pulmonary artery (PA) catheter, and questions have been raised regarding the risk/benefit ratio of this invasive technique.

Furthermore, great variations between measurements have been reported. Continuous thermodilution CO (CCO) measurement is reported to be a better alternative, but it still requires the placement of a PA catheter. Esophageal echo-Doppler

ultrasonography (ED) provides non-invasive continuous measurement of CO (ED-CO). This study was thus designed to compare the agreement between ED-CO and both thermodilution techniques (BCO and CCO). METHODS: Twenty-four patients undergoing primary coronary artery bypass graft surgery were randomized to have a PA catheter placed for measurement of either BCO or CCO. All patients also had an ED probe placed. In Group I patients (n = 12), BCO measurement was carried out every 15 minutes throughout the surgery except during cardiopulmonary bypass, with concurrent ED-CO reading recorded at the same time point. In Group II patients (n = 12), CCO and ED-CO measurements were recorded at the same designated points of time as in Group I. The agreement between methods (BCO vs. ED-CO or CCO vs. ED-CO) was assessed using Bland-Altman method. RESULTS: The range of measured CO of each method was 2.1 to 9.4 l/min for BCO, 2.4 to 9.2 l/min for CCO and 2.3 to 8.9 l/min for ED-CO. ED-CO and CCO had excellent agreement with a linear regression coefficient (r2 value) of 0.846, and a bias (mean difference) and SD of bias of 0.05 +/- 0.49 l/min. In contrast, the agreement between BCO and ED-CO was poorer; correlation was low (r2 value 0.406) and both the bias and SD of bias were high (0.11 +/- 1.12 l/min). Furthermore, BCO measurements had poor reproducibility, whereas both ED-CO and CCO measurements had good

reproducibility. CONCLUSIONS: Esophageal echo-Doppler ultrasonography is a satisfactory alternative for cardiac output measurement because it gives a value in good agreement with CCO measurement. With significant between-measurement

(2)

variations, the accuracy and precision of BCO are uncertain, and it should not be considered as the "gold standard".

Referanslar

Benzer Belgeler

In our retrospective study, adequate urine output, increased CI and decreased PCWP were observed in all of our patients who underwent cardiac surgery and having poor left ventricular

Quantification of septum dysfunction is done by echocardiography, and Table 1 displays the gradation of septal motion, its movement, and the degree of thickening observed

The prevalen- ce of Chlamydia pneumoniae in atherosclerotic and normal blood vessels of patients undergoing redo and first time coronary artery bypass graft surgery. Davidson M, Kuo

These include upper mini-sternotomy, lower mini-sternotomy, right anterior mini-thoracotomy, right anterolateral mini-thoracotomy, left anterolateral mini- thoracotomy,

An increased awareness of predisposing risk factors and the addition of intra- abdominal pressure measurement to the standard follow-up scheme, particularly in

Anastomosis/graft revision, new anastomosis/patch plasty to distal native artery or free left internal mammary artery graft was performed in 146 grafts of 143 patients in

Many studies have suggested that the normal coupling of cerebral blood flow with metabolism and usual cerebral blood flow-perfusion pressure relationship is lost

After performing cardiopulmonary bypass (CPB) and a left atriotomy, the tilting disc mitral valve was resected, and a bileaflet mechanical mitral valve was